Heat regulators on Danfoss batteries. Danfoss thermostators for heating and heating radiators

Reservoirs 17.06.2019
Reservoirs

The advantages of our products

Saving up to 46% of energy

Radiator thermostators allow you to spend exactly the amount of energy that is currently necessary to maintain a comfortable room temperature. Different thermostatic elements cope with this task in different ways. Compared with the manual adjustable valve, the thermostats with liquid or paraffin filling make it possible to save 31%, with gas filling - 36%. The use of electronic radiator thermostats Danfoss Living ECO allows you to save up to 46% of energy to heating.

* According to a study conducted by the Rhine-Westphalical Technical University,
g. Achen, Germany.

Fast reaction

DANFOSS RA series thermostators are equipped with gas filling bellows. The heat capacity of gas is significantly less than liquids and, moreover, paraffin. As a result, gas regulators with gas filling react much faster to change the temperature indoors. Therefore, Danfoss thermostators maintain a temperature with greater accuracy and provide greater energy savings. Radiator thermostat with a gas-filled thermostatic element ("gas") are patented and manufactured only by Danfoss.

Simple installation and configuration

A set of adapters will allow you to install Danfoss Living Eco thermostat on most thermostatic valves present in the market. Ensure yourself, looking at this short video.

Reliable work

Danfoss thermostators are fully adapted to work in Russian conditions. It makes it possible to approve this to us more than 40 years of experience of operating thermostators in Russia. For the first time in Moscow, Danfoss thermostators were installed in 1964 in the hotel "Russia", where they served before her demolition

Safety thermal heads for heating radiators

In thermal heads for radiators heating Danfoss. Living ECO provides a blocking function from children. The study of the surrounding world will be safe even for the smallest.

Comfort in all rooms

The amount of heat required by each room changes during the day. In the morning the sun shines in the windows on the eastern side of the house, at noon on the southern, evening on Western. If you control the heating of the whole house around the temperature in the same room, the temperature will change during the day.

Now you can buy a thermostat with modern design.

Red Dot - known worldwide "quality mark" in the field of industrial design. Only exceptionally from the point of view of aesthetics and functionality products are obtained by this high evaluation. In 2010, Danfoss was awarded Red Dot award for the development of the Living series thermostats.

In the countries of the post-Soviet space, up to 40% of energy resources goes to the needs of heating and ventilation of buildings, it is several times more than that of advanced European countries. The issue of energy saving costs sharply, more than ever, especially against the background of constant increase in the cost of energy carriers. One of the devices that save thermal energy in the house is the thermostat for the battery whose installation can reduce heat consumption up to 20%. But for this, it is necessary to correctly select regulators to the heating system and perform their installation, which will be told in this article.

The principle of operation of the thermostatic valve

The first thermostats for radiators designed to maintain a permanent temperature in the room were invented back in 1943 by Danfoss, she also owns the championship in the production and sale of such devices. For this reason, our article will rely on the materials and recommendations of the company Danfoss, whose many years of experience is not subject to doubt.

For the years since the invention, the thermostators for radiators were changed and became such as we know them. Structurally, they consist of two main elements: valve and thermal heads that are connected by a locking mechanism. The appointment of the thermal heads - perceive the temperature ambient And to regulate it, influence the actuator - the valve, it overlaps the flow of the coolant entering the heating device.

This method of regulation is called quantitative, since the device affects the flow rate of the coolant passing into the radiator. There is another method - high-quality, the temperature of the water in the system changes with it. This carries out a temperature controller (mixing unit), installed in a boiler room or thermal point.

To understand the principle of operation of the thermal heads, it is proposed to study the scheme of the device shown in the context:

Inside the element housing is a bellows filled with a heat-sensitive medium. It happens two types:

  • liquid;
  • gas.

Liquid bellows are easier in the manufacture, but losing gas to speed, so the latter got very widespread. So, with an increase in air temperature, the substance in the closed space expands, the bellows is stretched and presses on the valve stem. That, in turn, moves down a special cone that reduces the valve flow cross section. As a result, the flow rate of the coolant decreases. When cooling the ambient air, everything occurs in the reverse order, the number of flowing water grows to a maximum, this is the principle of operation of the thermostat.

Depending on the type of heating system and the installation conditions of the device, the sets of the thermal head can be used to control the flow of the coolant. different combinations. In one-tube heating systems, it is recommended to install valves with elevated throughput and low hydraulic resistance (marking Production of Danfoss - RA-G, RA-KE, RA-KEW).

The same recommendation concerns two-pipe samotane systems, where the coolant circulates naturally, without compulsory motivation. If the heating scheme is two-pipe with circulating pumpYou should choose a valve with the ability to adjust the bandwidth (Marking Danfoss - RA-N, RA-K, RA-KW). This adjustment is quite simple and the special tool is not needed for it.

When a question with the selection of the valve is resolved, you need to decide on the type of thermal head. They are offered in the following versions:

  1. With an internal thermoelement (as in the diagram presented above).
  2. With a remote temperature sensor.
  3. With an external regulator.
  4. Electronic (programmable).
  5. Antivandal.

An ordinary thermostat for heating radiators with an internal sensor is received to the installation, if it is possible to arrange its axis horizontally so that the air of the room freely washed the body of the instrument, as shown in Figure:

Attention! It is not allowed to install a thermostat for a battery in a vertical position, the thermal stream, rising from the feed pipe and the valve body, will influence the bellows, as a result of which the device will not work correctly.

If horizontal head mounting is not possible, it is better to purchase a remote temperature sensor in a set with a capillary tube with a length of 2 m. It is at such a distance from the radiator that this device can be placed by attaching it to the wall:

In addition to the vertical installation for buying a remote sensor, there are other objective reasons:

  • heating radiators with temperature regulator are behind dense curtains;
  • in the immediate vicinity of the thermal heads pass pipes with hot water or there is another source of heat;
  • the battery is under a broad windowsill;
  • the internal thermoelement enters the area of \u200b\u200bthe draft.

In rooms with high battery interior requirements, often hide under decorative screens from various materials. In such cases, the thermostat that fell under the casing registers the temperature of the hot air accumulating in the upper zone and can entirely block the coolant. Moreover, it is completely closed access to head control. In this situation, the choice should be made in favor of the remote controller combined with the sensor. Options for its placement are shown in Figure:

Electronic thermostats with display are also two types: with a built-in and removable control unit. The latter is characterized by the fact that the electronic unit is disconnected from the thermal head, after which it continues to function as usual. Assigning similar devices - adjustment of the temperature in the time of day in accordance with the program. This allows you to reduce the heating power in working timeWhen there are no one at home and in other similar cases, which leads to additional energy savings.

When there are small children in the house, which everyone wants to try their handles, it is better to establish an anti-vandal type thermostat with a casing that protects the settings of the device from unqualified intervention. This applies to the thermostats facing other public buildings: kindergartens, schools, hospitals, and so on.

How to install a thermostat on the battery

The first recommendation is not to put thermal heads on all heaters within sight. Here the following is the following: the regulation must be subjected to radiators whose total power is 50% or more of all in the same room. For example, when there are 2 heater in the room, then the thermostat should be equipped with 1 battery, whose power is greater.

Council. If pig-iron radiators are used as heating devices, then maintaining the microclimate using thermostatic valves will be ineffective. The fact is that work cast-iron batteries Very inertial, after overlapping the coolant flow, they emit heat for a long time and vice versa for a long time they accelerate. Installation of valves does not make sense, you will only spend your time and means.

The first part of the device is the valve - it is recommended to mount on the supply feed pipe at the time of connection of the radiator to heating system. In the case when it is required to embed it into the collected system, the feed liner will have to be dismantled. It will deliver some difficulties if the connection is executed steel pipesMake a tool for cutting pipes and cutting threads.

After the thermostat on the heating battery is set, the thermal head is mounted without a tool. It is enough just to combine tags on the housings and smoothly pressing the head in the nest. The signal will serve as a fixing mechanism.

It is a bit more difficult to install an anti-vandal thermostat, for this you will need a hex key of 2 mm. By combining the required tags, as shown in the diagram, you need to press the thermal head, and the hexagon is tightened to the locking bolt on the side.

Installation of the remote sensor and the regulator is carried out on the parts free of the interior parts and furniture, placing them at an altitude of 1.2-1.6 m from the floor, as shown in the diagram:

First, the mounting plate is attached to the wall to the wall, and then the housing is snapped by simply by pressing it. The capillary tube is fixed to the wall of plastic homutics, as a rule, they are included with the product.

In addition to the standard temperature adjustment in the heads, the thermostat is set to the maximum and minimum limits, on which the rotation of the wheel becomes impossible. This contains restrictive pins that are in the rear of the product. You need to pull out one of them and after debugging the system insert into the hole under the appropriate label:

Conclusion

To make a selection of the thermostat - the task is simple, it is important to understand what the valve is purchased under which heating system is purchased and know where it will be. Definitely recommended programmable devices, as the most economical.

On this page you can find and download automation instructions, regulators, modules, thermostats, ... Danfoss in PDF format.

      Adjusting rA-N valves and RA-NCX are designed for use in two-pipe pumping systems Water heating. 2009 | Language: RU | PDF 1.27 MB.

      The Danfoss Series PFM 5000 Standard series is designed to measure pressure drop, flow and temperature, for hydraulic balancing of heat and cold supply systems. User's manual. Language: RU | PDF 887.60 KB.

      AME 55 QM Series Danfoss Reducer Electric Drives. Technical description. Language: RU | PDF 136.45 Kb.

      AMI 140 Danfoss series electric drives for a two-position control. Technical description. Language: RU | PDF 1.10 MB.

      Reducer electric drives Danfoss AMV 110 NL, AMV 120 NL. Technical description. Language: RU | PDF 122.06 Kb.

      The thermostatic element of the Danfoss Qt series is the reverse coolant temperature controller when used with AB-QM valve. Technical description. Language: RU | PDF 1.29 MB.

      Automated information measuring system Comfort Contour. Danfoss brochure. Language: RU | PDF 4.65 MB.

      Danfoss Controllers ECA Connect Series. Passport. Language: RU | PDF 361.34 KB.

      Thermoelectric Drives Danfoss ABNM Series (normally closed) with analog control. Technical description. Language: RU | PDF 327.77 KB.

      Thermoelectric drives Danfoss series ABV. Technical description. Language: RU | PDF 138.87 KB.

      Reductor electric drives Danfoss AMV 162/182 series (230 V) for rotary control valves. Installation instructions. Language: RU | PDF 1.34 MB.

      Ame 10 - EI96L11F series Danfoss electric drives. User's manual. Language: EN, DE, IT, PL, FR, ES | PDF 799.92 KB.

      Reducer electric drives DANFOSS AME 15 series (ES), AME 16, AME 25, AME 35. Technical description. Language: RU | PDF 605.78 KB.

      Reducer electric drives Danfoss Ame 85 series, AME 86. Technical description. Language: RU | PDF 487.78 KB.

      Ame 130, AME 140, AME 130H, AME 140H, AME 130, AME 140H gearboxes. Technical description. Language: RU | PDF 864.29 KB.

      Reducer electric drives Danfoss AMV Series 435. Technical Description. Language: RU | PDF 930.12 KB.

      Reducer electric drives DANFOSS AMV 438SU series (with a return spring). Technical description. Language: RU | PDF 687.15 Kb.

      Thermoelectric drives Danfoss TWA series. Technical description. Language: RU | PDF 285.27 KB.

      Embedded input / output units Danfoss ECA 32 Series for ECL COMFORT 310 / 310B controllers. Technical description. Language: RU | PDF 757.87 KB.

      Danfoss Temperature Controllers ECL Series Comfort 110 for Heating and Hot Water Supply Systems (DHW). Technical description. Language: RU | PDF 767.25 Kb.

      Universal Danfoss Temperature Controllers Series ECL Comfort 210/210 V and ECA Remote Control Unit 30. Technical Description. Language: RU | PDF 1.16 MB.

      Universal Danfoss Temperature Controllers of the ECL Comfort 310/310 V Series and ECA Remote Control Unit 30. Technical Description. Language: RU | PDF 1.25 MB.

      Programming keys Danfoss series A214, A314 for ECL temperature regulators Comfort 210/310. Operating instructions. Language: RU | PDF 5.56 MB.

      The electronic key of the Danfoss application A217, A317 series for ECL Comfort 210/310 temperature regulators. Instructions for use. Language: RU | PDF 4.08 MB.

      A230 Series Danfoss Programming Keys for ECL Comfort 210/310 Temperature Regulators. Operating Instructions. Language: RU | PDF 2.43 MB.

      DANFOSS A231, A331 Series Programming Keys for ECL Comfort 210/310 Temperature Regulators. Operating Instructions. Language: RU | PDF 3.16 MB.

      A260 Series Danfoss Programming Keys for ECL Comfort 210 Temperature Regulators. Operating Instructions. Language: RU | PDF 2.02 MB.

      A266 series Danfoss programming keys for ECL Comfort 210/310 temperature regulators. Operating instructions. Language: RU | PDF 3.52 MB.

      A275, A375 Series Danfoss Programming Keys for ECL Comfort 210/310 Temperature Regulators. Operating Instructions. Language: RU | PDF 6.43 MB.

      A275, A375 Series Danfoss Programming Keys for ECL Comfort 210/310 Temperature Regulators. Installation Instructions. Language: RU | PDF 3.05 MB.

      A361 Series Danfoss Programming Keys for ECL Comfort 310 Temperature Regulators. Operating Instructions. Language: RU | PDF 2.92 MB.

      A361 Series Danfoss Programming Keys for ECL Comfort 310 Temperature Regulators. Installation Instructions. Language: RU | PDF 1.34 MB.

      A368 Series Danfoss Programming Keys for ECL Comfort 310 Temperature Regulators. Operating Instructions. Language: RU | PDF 3.08 MB.

      A368 Series Danfoss Programming Keys for ECL Comfort 310 Temperature Regulators. Installation instructions. Language: RU | PDF 3.64 MB.

      A376 Danfoss Programming Keys for ECL Comfort 310 Temperature Regulators. Operating Instructions. Language: RU | PDF 5.06 MB.

      A376 series Danfoss programming keys for ECL Comfort 310 temperature regulators. Installation instructions. Language: RU | PDF 2.31 MB.

      Communication capabilities of Danfoss temperature regulators ECL COMFORT 210/310 series. Operating instructions. Language: RU | PDF 673.15 Kb.

      OPC server for Danfoss temperature regulators ECL COMFORT 310 series. Operating instructions. Language: RU | PDF 999.75 Kb.

      USB driver. Connecting the ECL Comfort 210/310 temperature regulators to the PC. Installation instructions. Language: RU | PDF 223.44 Kb.

      New Danfoss ECL COMFORT 210/310 controllers are extended functionality and maximum efficiency. Brochure. Language: RU | PDF 2.97 MB.

      Danfoss Temperature Controllers Series ECL Comfort 210/310. User Guide. Language: RU | PDF 3.85 MB.

      Selection of ECL keys. User's manual. Language: RU | PDF 267.81 KB.

      Selection of ECL keys. User's manual. Translation table with codes. Language: RU | PDF 18.62 KB.

      Switching panel Danfoss series FH-WC to control floor heating systems. Technical description. Language: RU, EN, DE, IT, FR | PDF 85.25 Kb.

      Danfoss Switching Panel FH-WC (230V) Series to control outdoor heating systems. Installation instructions. Language: RU, EN, DE, IT, FR | PDF 2.37 MB.

      Cabinet with an apartment joining an apartment heating system-1-B1 (ShKSO-1-B1). Technical description. Language: RU | PDF 1.18 MB.

      Wardrobe with an apartment joining the heating system-1-B4, B7 (ShKSO-1-B4, B7). Technical description. Language: RU | PDF 1.24 MB.

      Cabinet with an apartment joining an apartment heating system of ShKSO-1 B1 to connect one apartment. Instructions for maintenance. Language: RU | PDF 1.28 MB.

      Cabinet with an apartment joining an apartment heating system of ShKSO-1 B1 to connect one apartment. Installation instructions. Language: RU | PDF 1.04 MB.

      Apartment heat meters Danfoss M-Cal Compact series (Modification 447). Passport. Language: RU | PDF 241.12 KB.

      Apartment heat meters Danfoss M-Cal Compact series (Modification 447). Brochure. Language: RU | PDF 246.47 KB.

      Apartment heat meters Danfoss M-CAL MS series. Passport. Language: RU | PDF 498.30 KB.

      Apartment heat meters Danfoss M-CAL MS series. Technical description. Language: RU | PDF 202.01 KB.

      Apartment heat meters Danfoss series M-CAL MS for measuring, processing and presenting the current and archival information about the amount of thermal energy consumed, about temperature, coolant consumption, and related data in closed water heating systems of individual consumers (consumers' consumers). Information booklet. Language: RU | PDF 444.39 KB.

      Apartment heat meters Danfoss Series Sonometer 500. Passport. Language: RU | PDF 293.87 KB.

      Ultrasonic apartment heat meters Danfoss Series Sonometer 500 for measuring, processing and presenting current and archival information about the amount of thermal energy consumed, temperature, coolant consumption and other data in closed water heating systems of individual consumers (apartments, cottages, office space). Information booklet. Language: RU | PDF 394.82 KB.

      Ultrasonic apartment heat meters Danfoss Series Sonometer 1100 for measuring, processing and presenting current and archival information about the amount of thermal energy consumed, temperature, coolant consumption and other data in closed water heating systems of individual consumers (apartments, cottages, office space). Information booklet. Language: RU, EN | PDF 242.78 KB.

      Ultrasonic apartment heat meters Danfoss Series Sonometer 1100. Passport. Language: RU, EN | PDF 1.23 MB.

      Remote controller MBUS id \u003d 0x2f for apartment heat meters Danfoss Series Sonometer 1100. Instructions for use. Language: RU, EN | PDF 1.70 MB.

      Apartment heat meters Danfoss Series Sonometer 1000. Passport. Language: RU, EN | PDF 1.68 MB.

      Ultrasonic Sono 1500 CT flow meter for measuring the flow and volume of various liquids at utility facilities and in other industries in technological and accounting and calculated operations. Passport. Language: RU | PDF 400.05 Kb.

      Thermal SPT 943 for measuring and taking into account thermal energy and the amount of heat carrier in closed and open water supply water systems. User's manual. Language: RU | PDF 607.48 Kb.

      Danfoss Pulse Signal Converters Hydro Port Pulse Series To connect to M-BUS network of resource accounting devices with a pulse output. Passport. Language: RU | PDF 300.96 KB.

      Danfoss Hydro Port Pulse Pulse Signals Pulse Signals. Technical description. Language: RU | PDF 139.01 KB.

      Izar Port Pulse Mini Pulse Mini Pulse Signals Converters. Passport. Language: RU | PDF 252.97 KB.

      Izar Port Pulse Mini Pulse Mini Pulse Signals Converters. Technical description. Language: RU | PDF 128.78 KB.

      DANFOSS DANFOSS COMPUTERS, IZAR CENTER MEMORY - M-BUS signals converters. Passport. Language: RU | PDF 360.97 KB.

      Danfoss Danfoss Series Center Series, Izar Center Memory 60, 120, 250 - M-BUS Signal Converters. Technical description. Language: RU | PDF 277.00 Kb.

      The system of dispatching of individual accounting of thermal energy M-BUS. Technical information for designers, installers, engineers selling. Language: RU | PDF 727.36 Kb.

      Radiator counters - Danfoss distributors of the Indiv-3, Indiv-3R, Indiv-3R2, INDIV-3RD series. Passport. Language: RU | PDF 460.78 KB.

      Radiator distributors The heat of Indiv-3 for organizing quarterly heat metering in residential buildings with a vertical wiring of the heating system. Information booklet. Language: RU | PDF 486.92 KB.

      Danfoss Pulse Adapter Indiv Pad Series. Technical description. Language: RU | PDF 253.81 KB.

      Indiv RM Radio Set for Personal Computer. Technical description. Language: RU | PDF 198.32 Kb.

      Network nodes NNV- and NNB-. Installation and operation instructions. Language: RU | PDF 515.57 KB.

      Individual Energy Directorate Danfoss AMR Series AMR series with remote wireless reading instrument readings. Installation and operation instructions. Language: RU | PDF 647.70 KB.

      Danfoss Pulse Adapter Indiv Pad Series. Passport. Language: RU | PDF 338.95 Kb.

      Network nodes Danfoss series NNB, NNV. Passport. Language: RU | PDF 335.04 KB.

      Designing an Indiv AMR system. Information booklet. Language: RU | PDF 5.70 MB.

      Danfoss electronic devices of the IndiV-5, Indiv-5R, Indiv-5R-1 series for thermal energy distribution. Passport. Language: RU | PDF 282.60 KB.

      Installation of meters - Danfoss heat distributors of the Indiv-5 series (5R) on bimetallic radiators. Installation instructions. Language: RU | PDF 1.16 MB.

      Installation of meters - heat distributors Danfoss series Indiv-5 (5R) on cast-iron sectional radiators. Installation instructions. Language: RU | PDF 908.17 Kb.

      Installing meters - Danfoss heat distributors of the Indiv-5 series, Indiv-5R on the Accord Convectors. Installation instructions. Language: RU | PDF 1.01 MB.

      Installation of meters - Danfoss heat distributors of the Indiv-5 series, Indiv-5R on the "Universal" convectors with a welded bracket. Installation instructions. Language: RU | PDF 2.54 MB.

      Installation of meters - Danfoss heat distributors of the Indiv-5 series, Indiv-5R on the "Universal" convectors with a straight valve. Installation instructions. Language: RU | PDF 3.03 MB.

      Installation of meters - Danfoss heat distributors of the Indiv-5, Indiv-5R series at the Universal Convectors with the U-Bend valve. Installation instructions. Language: RU | PDF 3.01 MB.

      Installing counters - Danfoss heat distributors of the Indiv-5 series (5R) on panel radiators. Installation instructions. Language: RU | PDF 906.56 Kb.

      Danfoss Radiator Distributors of the Indiv series (modifications Indiv-5, Indiv-5R). Information booklet. Language: RU | PDF 1.02 MB.

      Danfoss Radiator Distributions Series Indiv-5, Indiv-5R. User's manual. Language: RU | PDF 122.73 Kb.

      Pressure regulators "to ourselves" Danfoss series AVA (PN 25 / DN 15 - 50). Installation and operation instructions. Language: RU, EN, DE, IT, FR, ES | PDF 1.70 MB.

      Pressure regulators "to ourselves" Danfoss AVA-AVDS series. Service kits. Installation instructions. Language: RU, EN, DE, IT, FR, ES | PDF 4.76 MB.

      Valves - pressure regulators "to ourselves" Danfoss AVA series (RU 25). Technical description. Language: RU, EN, DE, IT, FR, ES | PDF 591.49 KB.

      Pressure regulators "After" Danfoss AVD series, AVDS - PN 16, 25 / DN 15 - 50. Installation and operation instructions. Language: RU, EN, DE, IT, FR, ES | PDF 2.62 MB.

      Valves - pressure regulators "After" Danfoss AVD series - for water, AVDS - for steam (RU 25). Technical description. Language: RU, EN, DE, IT, FR, ES | PDF 1.02 MB.

      Valves - pressure regulators "to ourselves" Danfoss AVDO series. Technical description. Language: RU | PDF 721.33 KB.

      Control regulators Danfoss AVDO2 series. Installation and operation instructions. Language: RU | PDF 698.14 KB.

      Pressure regulators "to ourselves" Danfoss AVDO series. User's manual. Language: RU | PDF 827.43 Kb.

      Valves - pressure drop controls Danfoss AVP series - with variable adjustment for the feed and return pipe; AVP-F - with fixed tuning for the return pipeline (RU16). Technical description. Language: RU, EN | PDF 2.44 MB.

      Danfoss Pressure Delta Regulators AVP Series, AVP-F. Accessories SP AV. Installation instructions. Language: RU, EN | PDF 739.51 KB.

      Danfoss Pressure Delta Regulators AVP Series, AVP-F (SP AV PN 16). Service kits. Installation and operation instructions. Language: RU, EN | PDF 1.42 MB.

      Danfoss Pressure Delta Regulators AVP Series, AVP-F (PN 16,25 / DN 15 - 50). Installation and operation instructions. Language: RU, EN | PDF 2.11 Mb.

      Danfoss Pressure Delta Regulators AVP series, AVP-F (SP AV PN 25). Service kits. Installation and operation instructions. Language: RU, EN | PDF 1.79 MB.

      Danfoss Pressure Delta Regulators AVP Series, AVP-F. Accessories. Installation and operation instructions. Language: RU, EN | PDF 748.53 KB.

      Valves - pressure drop controls Danfoss AVP series - with variable adjustment for the feed and return pipe; AVP-F - with fixed tuning for the return pipeline (RU 25). Technical description. Language: RU, EN | PDF 1.21 MB.

      Danfoss temperature regulators AVTB series. Technical description. Language: RU | PDF 776.24 KB.

      Danfoss Danfoss AVTB Series Temperature Controllers. Installation instructions. Language: RU | PDF 1.63 MB.

      Danfoss Temperature Controllers AVTB Series, Sensor Ø9.5 / 180 mm. User's manual. Language: RU | PDF 80.08 KB.

      Danfoss temperature regulators AVTB series. Installation instructions. Language: RU | PDF 655.69 KB.

      Temperature regulators RAVK / RAV8 (VMT8, VMA, VMV) of direct action for applying hot water systems of small buildings (cottages). Technical description. Language: RU | PDF 1.09 MB.

      Temperature regulators RAVK (25-45 ° C). Installation and operation instructions. Language: RU | PDF 1.48 MB.

      Temperature regulators RAVK (25-65 ° C). Installation and operation instructions. Language: RU | PDF 1.49 MB.

      Pressure regulators "to ourselves" Danfoss AFA / VFG 2 series (21) DN 15-250. Installation and operation instructions. Language: RU, EN, DE, IT, FR | PDF 6.02 MB.

      Pressure regulators "to ourselves" Danfoss AFA / VFG 2 series (21). Technical description. Language: RU, EN, DE, IT, FR | PDF 884.65 KB.

      Pressure regulators "After" Danfoss AFD series AFD / VFG (S) 2 (21) DN 15-250. Installation and operation instructions. Language: RU, EN, DE, IT, FR | PDF 3.74 MB.

      Pressure regulators "After" Danfoss AFD series AFD / VFG2 (21), AFD / VFGS2 (for steam). Technical description. Language: RU, EN, DE, IT, FR | PDF 951.72 KB.

      Danfoss Pressure Delta Regulators Series AFP / VFG 2 (21) DN 15 - 250. Installation and Operation Instructions. Language: RU, EN, DE, IT, FR | PDF 3.37 MB.

      DANFOSS DANFE DETAILATORS AFP / VFG Series 2. Technical Description. Language: RU, EN, DE, IT, FR | PDF 849.64 KB.

      Danfoss DNFOSS Series AFPA / VFG 2 (21) DN 15-250 Series Dump Regulators. Installation and operation instructions.

      Bypass valves Danfoss. AFPA / VFG series 2. Technical description. Language: RU, EN, DE, IT, FR | PDF 678.71 KB.

      Bypass valves (regulators) Danfoss series AVPA PN 16, 25 / DN 15 - 50. Installation and operation instructions. Language: RU, EN, DE, IT, FR | PDF 2.17 MB.

      Bypass valves (regulators) Danfoss AVP series (RU 16 and RU 25). Technical description. Language: RU, EN, DE, IT, FR | PDF 887.98 KB.

      Pressure drop regulators, Danfoss flow limiters AFPB series (-f) / VFQ2 (21) DU 15-125. Installation and operation instructions. Language: EN, DE, FR | PDF 597.42 Kb.

      Danfoss Danfoss Pressure Regulators AFPB-F / VFQ2 Series with a fixed setting and manual flow limit. Technical description. Language: EN, DE, FR | PDF 197.75 Kb.

      Pressure drop regulators, DANFOSS flow limiters AFPQ series (4) / VFQ 2 (21) DN 15 - 250. Installation and operation instructions. Language: EN, DE, FR | PDF 601.56 Kb.

      Pressure drop controls with automatic DANFOSS flow limit AFPQ / VFQ2 series - to install on the return pipe, AFPQ 4 / VFQ2 - to install on the supply pipeline. Technical description. Language: EN, DE, FR | PDF 651.95 KB.

      Danfoss flow regulators AFQ / VFQ 2 DN 15 - 250 series. Installation and operation instructions. Language: EN, DE, FR | PDF 1.23 MB.

      Danfoss flow regulators AFQ / VFQ series 2. Technical description. Language: EN, DE, FR | PDF 503.85 KB.

      Drives Danfoss AFT 06, 26, 17, 27 for temperature regulators. Installation and operation instructions. Language: RU, EN, DE, IT, FR | PDF 2.72 MB.

      Thermostatic elements of the Danfoss series AFT 06, 26, 17, 27 for temperature regulators. Technical description. Language: RU, EN, DE, IT, FR | PDF 247.06 Kb.

      Danfoss Pressure Delta Regulators AVPB, AVPB-F Series, AVPBT, AVPBT-F (PN 16,25 / DN 15 - 50) with manual flow limit. Installation and operation instructions. Language: RU, EN, DE, IT, FR | PDF 3.01 MB.

      Danfoss Danfoss Delta Regulators Series AVPB, AVPB-F (RU 25) with manual flow limit. Technical description. Language: RU, EN, DE, IT, FR | PDF 1.07 MB.

      Danfoss Pressure Pressure Regulators AVPB Series, AVPB-F (RU 16) with manual flow limit. Technical description. Language: RU, EN, DE, IT, FR | PDF 1.90 MB.

      Danfoss Pressure Delta Regulators AVPQ Series, AVPQ-F, AVPQ 4, AVPQT (PN 16,25 / DN 15 - 50) with automatic flow limit. Installation and operation instructions. Language: RU, EN, DE, IT, FR | PDF 3.25 MB.

      Danfoss Danfoss Pressure Regulators, AVPQ 4 Series (RU 25) with automatic flow limit. Technical description. Language: RU, EN, DE, IT, FR | PDF 1.41 MB.

      Danfoss Danfoss Pressure Regulators AVPQ Series, AVPQ-F (RU 16) with automatic flow limit. Technical description. Language: RU, EN, DE, IT, FR | PDF 1.97 MB.

      DANFOSS Flow Limpers Controllers AVQ Series (In combination with a temperature controller - AVQT) PN 16, 25 / DN 15 - 50. Installation and operation instructions. Language: RU, EN, DE, IT, FR | PDF 2.99 MB.

      Danfoss flow regulators AVQ series (RU 25) for feed and return pipelines. Technical description. Language: RU, EN, DE, IT, FR | PDF 496.04 KB.

      Danfoss flow regulators AVQ series (RU 16). Technical description. Language: RU, EN, DE, IT, FR | PDF 482.70 KB.

      Danfoss temperature regulators AVT series. Installation and operation instructions. Language: RU, EN, DE, IT, FR | PDF 3.05 MB.

      Danfoss temperature regulators AVT / VG series - with external thread, AVT / VGF - flange (RU 25). Technical description. Language: RU, EN, DE, IT, FR | PDF 887.47 KB.

      Danfoss temperature regulators AVTQ series. Installation and operation instructions. Language: RU, EN | PDF 1.02 MB.

      Danfoss Temperature Controllers AVTQ Series (Du 20) with consumption correction. Technical description. Language: RU, EN | PDF 485.27 KB.

      Danfoss temperature regulators AVTQ series (DU 15) with consumption correction. Technical description. Language: RU, EN | PDF 680.90 KB.

      FJV Danfoss Temperature Controllers. Installation and operation instructions. Language: RU, EN | PDF 566.50 KB.

      Reverse Coolant Temperature Regulators Danfoss FJV Series. Technical description. Language: RU, EN | PDF 354.36 KB.

      Reverse Coolant Temperature Regulators Danfoss FJV Series. Passport. Language: RU, EN | PDF 221.26 Kb.

      Danfoss temperature regulators Ravi series. Installation and operation instructions. Language: RU | PDF 1.66 MB.

      Danfoss Temperature Regulators Ravi / RAV8 Series (VMT8, VMA, VMV). Technical description. Language: RU | PDF 986.78 KB.

      Danfoss temperature regulators of the RAVV series. Installation and operation instructions. Language: RU | PDF 1.23 MB.

      Danfoss temperature regulators of the RAVV / RAV8 series (VMT8, VMA) for use in hot water systems of small buildings (cottages). Technical description. Language: RU | PDF 1.13 MB.

The main task of any heating system is to provide a comfortable air temperature in the room. This temperature can be different depending on the purpose of the room, but if mandatory condition It is its immutability during the day, the thermostat becomes an indispensable structural element of the heating device.
Danfoss radiator thermostat consists of two parts: valve and thermostatic element (thermal heads). Inside the thermostatic element is a thin hermetic cylinder - a belliff filled with liquid or gaseous heat-sensitive working substance. When the temperature is raised, the bellows stretch and moves the rod associated with it, which presses on the rod in the valve, and the valve reduces the coolant flow into the radiator. When the temperature decreases, the process goes in reverse order. Thus, the thermal head is the control mechanism, and the valve is executive.

Manufacturer: Danfoss (Denmark).

Danfoss radiator thermostators valves

Valves of radiator thermostators are divided into:
- valves for a two-pipe pumping system of heating (type Ra-n) of increased resistance with the installation device of their bandwidth for performing hydraulic balancing of the pipeline system;
- Valves of increased bandwidth type Ra-G for pumping single-tube or two-pipe gravitational heating system.

Valve housings Danfoss are made of brass. The compound provides a simple and accurate mounting of the thermostatic element on the adjusting valve. To identify Ra-N valves, their protective caps are painted in red, and Ra-G is in gray.

Danfoss RA-G thermoregulators valves

RA-G 15 The RA-G 15 thermostat valve for a single-tube or two-pipe system, by type of connection - direct or angular, connecting size is 1/2 inches (Du 15).1 930 rub.
RA-G 20 The RA-G 20 thermostat valve for a single-tube or two-pipe system, by type of connection - direct or angular, connecting size is 3/4 inches (Du 20).2 460 rub.
RA-G 25 RA-G 25 thermostat valve for a single-pipe or two-pipe system, by type of connection - direct or angular, connecting size is 1 inch (Du 25).3 100 rubles.

Danfoss RA-N thermoregulators valves

RA-N 15 The RA-N 15 thermostat valve for a two-pipe system, by type of connection - direct or angular, connecting size is 1/2 inches (Du 15).1 600 rub.
RA-N 20 The RA-N 20 thermostat valve for a two-pipe system, by type of connection - direct or angular, connecting size is 3/4 inches (Du 20).2 000 rubles.
RA-N 25 The valve of the RA-N 25 thermostat for a two-pipe system, by type of connection - direct or angular, connecting size is 1 inch (Du 25).3 600 rub.

With the valves of the RA-G and RA-N series, you can combine the RA series.


Thermostatic element and radiator valve

A set of Danfoss thermostatic equipment consists of a radiator valve Ra-G (for a single-tube or two-pipe heating system) or Ra-n (for a two-pipe heating system) and the thermostatic element Ra.
The kit is intended for automatic control of air temperature in the room.
Easily installed on different types Heating devices in a quarter area with a centralized single-tube and two-pipe heating system.

RA 2994 / RA-G 15 straight Article 013G2164B.
The direct valve of the RA-G 15 thermostat for a single-tube or two-pipe system, the thermostat Ra 2994.
2 990 rubles.
RA 2994 / RA-G 15 corner Article 013G2163B.
The angle valve of the RA-G 15 thermostat for a single-tube or two-pipe system, the thermostat Ra 2994.
2 990 rubles.
RA 2940 / RA-G 15 straight Article 013G2144.
The direct valve of the thermostat Ra-G 15 for a single-pipe or two-pipe system, the thermostat Ra 2940.
3 200 rubles.
RA 2940 / RA-G 15 corner Article 013G2143.
The angle valve of the RA-G 15 thermostat for a single-tube or two-pipe system, the thermostat Ra 2940.
3 200 rubles.
RA 2994 / RA-G 20 straight Article 013G2166B.
The direct valve of the thermostat Ra-G 20 for a single-tube or two-pipe system, the thermostat Ra 2994.
3 390 rubles.
RA 2994 / RA-G 20 corner Article 013G2165B.
The angle valve of the RA-G 20 thermostat for a single-tube or two-pipe system, the thermostat Ra 2994.
3 390 rubles.
RA 2940 / RA-G 20 straight Article 013G2146.
Direct valve thermostat Ra-G 20 for a single-tube or two-pipe system, thermostat Ra 2940.
3,690 rubles.
RA 2940 / RA-G 20 corner Article 013g2145
Corner valve RA-G 20 thermostat for a single-tube or two-pipe system, thermostat Ra 2940.
3,690 rubles.
RA 2940 / RA-N 15 straight Article 013g2154
The direct valve of the RA-N 15 thermostat for a two-pipe system, the thermostat Ra 2940.
2 900 rub.
RA 2940 / RA-N 15 corner Article 013G2153.
The angle valve of the thermostat Ra-N 15 for a two-pipe system, the thermostat Ra 2940.
2 900 rub.
RA 2940 / RA-N 20 straight Article 013G2156.
Direct valve thermostat Ra-N 20 for a two-pipe system, thermostat Ra 2940.
3 290 rubles.
RA 2940 / RA-N 20 corner Article 013g2155
The angle valve of the RA-N 20 thermostat for a two-pipe system, the thermostat Ra 2940.
3 290 rubles.

Thermostatic elements of Danfoss.

Thermostatic elements (thermal heads) Danfoss are automatic temperature control devices intended for a complete set of radiator thermostators.
The thermostat equipped with a thermostatic element maintains a constant temperature in the room at the desired level in the range from + 5 ° C to + 26 ° C with an accuracy of ± 1 ° C.
It should be remembered that thermostators are mostly regulatory reinforcement but not shut-off (With the exception of the thermostats RA2940 and RAW 5110), so if you need to disassemble the radiator, the thermal head should be replaced with a bronze shut-off handle, which will ensure the complete overlap of the coolant flow.

Thermostatic elements of Danfoss.

RA 2994. Thermostatic element with a gas-filled temperature sensor. Temperature adjustment range: from + 5 ° C to + 26 ° C.1 440 rub.
RA 2992. Thermostatic element with a gas-filled remote temperature sensor. Temperature adjustment range: from + 5 ° C to + 26 ° C. The length of the Capillary Tube: 2 m.2 200 rubles.
RA 2920. Thermostatic element with a gas-filled temperature sensor and protection against unauthorized intervention. Temperature adjustment range: from + 5 ° C to + 26 ° C.2 190 rub.
RA 2940. Thermostatic element with a gas-filled temperature sensor. Temperature adjustment range: from + 0 ° C to + 26 ° C. The possibility of overlapping the supply of the coolant.1 600 rub.
RAW 5010. Thermostatic element with liquid temperature sensor. Temperature adjustment range: from + 8 ° C to + 28 ° C.1 390 rub.
RAW-K. Thermostatic element with liquid temperature sensor. Temperature adjustment range: from + 8 ° C to + 28 ° C.
To install on the built-in valves (M30X1.5) of the bottom liner - Rifar, Copa, Kermi, Demrad, Stelrad, Purmo, Korado.
1 390 rub.
Thermostatic remote control member with liquid temperature sensor. Temperature adjustment range: from + 8 ° C to + 28 ° C. Length of the capillary tube: 2 m (Ra 5062), 5 m (RA 5065).

4 590 rubles.

4 960 rub.

By installing thermostat, it should be remembered that the effect of their use will be tangible if they control radiators with low thermal inertia. Practically, these are all the well-known types of modern radiators besides cast iron. The latter, due to the large mass of the cast iron and the water will be heated and cool very slowly, reducing the control effect.

RLV shut-off and connecting valves are designed for lateral connection to the radiator of pipelines of a two-pipe heating system. We are produced in direct and corner execution.
P y \u003d 10 bar *; T max \u003d 120 ° C; ΔР Max \u003d 0.6 bar.

* Conditional pressure. See GOST 356-80 fittings and pipelines. Conditional pressure, trial and workers.

LLC "PROMARMATURE XXI Century" offers a wide range of Danfoss products

A range of products includes: | | | | | | |
Danfoss is the world's largest manufacturer of radiator thermostators. Over the years, Danfoss sold more than 300 million radiator thermostators around the world, which saves a million fuel liters daily and prevent harm caused by the nature of carbon dioxide tons, sulfur compounds and other harmful substances. Radiator thermostators pay off in less than two years, and the standard service life of more than 20 years is a great opportunity to save money and energy.

Danfoss radiator thermostators are manufactured with embedded and remote sensors to ensure optimal functioning; Plus a wide range of valves and additional equipment make up the widest range of our products.

Thermostatic elements of the RA 2000 series

Thermostatic elements of the RA 2000 series are automatic temperature control devices designed to complete the RA radiator thermostators. The radiator thermostat is a proportional direct-action air temperature regulator with a small proportion zone, which is currently equipped with systems for the heating of buildings of various purposes. The thermostat Ra consists of two parts:

  • universal thermostatic element of the RA 2000 series;
  • adjusting valve with pre-tuning bandwidth Ra-N (for two-pipe heating systems) or RA-G (for a single-tube system). The program of production of thermostatic elements of the RA 2000 series includes:
  • RA 2994 and RA 2940 with a built-in temperature sensor, protection of the heating system from freezing, a range of temperature setting 5-26 ° C, a device for fixing and restricting the temperature setting. In contrast to Ra 2990, the thermoelectric Ra 2940 additionally has a function that provides 100% overlap of the thermostat valve;
  • RA 2992 - thermoelements with a remote sensor, protection of the heating system from freezing, a range of temperature setting 5-26 ° C, a device for fixing and restricting the temperature setting;
  • RA 2920 - Thermal elements with a casing that protects against unauthorized intervention, built-in sensor, freezing protection, a range of temperature setting 5-26 ° C, a device for fixing and restricting the temperature setting;
  • RA 2922 - Thermal elements with a casing that protects against unauthorized interference, a remote sensor, freezing protection, a range of temperature setting 5-26 ° C, a device for fixing and restricting the temperature setting. Ra 2992 and Ra 2922 are equipped with an ultra-thin capillary tube with a length of 2 m, which is inside the body of the remote sensor, connecting it with the thermostatic element working bellows. In the installation process, the tube is pulled out to the required length. The RA 5060/5070 series is a number of remote control thermoelements with the protection of the heating system from freezing, the temperature setting range is 8-28 ° C, a device for fixing and restricting the temperature setting:
  • RA 5062 - with a length of the capillary tube 2 m;
  • RA 5065 - with a capillary tube length 5 m;
  • RA 5068 - with a capillary tube length of 8 m;
  • Ra 5074 - with a capillary tube 2 + 2 m.

    All thermostatic elements can be combined with any regulating valves of type RA. Clip connection provides simple and accurate mounting of the thermoelement on the valve. The protective cover of thermoelements RA 2920 and RA 2922 prevents their unauthorized dismantling and reconfiguration to unauthorized persons. The technical characteristics of the radiator thermostators of the type RA correspond to European standards EN 215-1 and Russian GOST 30815-2002.

    Specifications of thermostatic elements of the RA 2000 series

    The main device of the thermostatic element is a bellows that provides proportional regulation. The thermoelement sensor perceives the change in the ambient temperature. The bellows and the sensor are filled with an easy-to-sleep liquidity and its pairs. The adjusted pressure in the bellows corresponds to the temperature of its charging. This pressure is balanced by the power of the tuning springs. With increasing air temperature around the sensor, part of the fluid evaporates, and the pressure of vapors in the bellows grows. In this case, the bellows increase in the volume by moving the valve spool towards the closing of the hole for the coolant duct into the heater until the balance between the spring force and the vapor pressure is reached. When the air temperature decreases, the pairs are condensed, and the pressure in the bellows decreases, which leads to a decrease in its volume and the movement of the valve spool towards the opening to the position in which the equilibrium of the system will again be established. Steam filling will always be condensed in the coldest part of the sensor, usually most remote from the valve body. Therefore, the radiator thermostat will always respond to changes in room temperature, which does not feel the temperature of the coolant in the underwater pipeline. However, when the air around the valve is still heated by heat, given by the pipeline, the sensor can register a higher temperature than indoors. Therefore, it is recommended to establish thermostatic elements to eliminate this influence, as a rule, in a horizontal position. Otherwise, it is necessary to apply thermoelements with a remote sensor.

    Select the type of thermostatic element

    Thermostatic elements with built-in sensor

    When choosing a thermostatic element, it should be guided by the rule: the sensor should always react to the air temperature in the room.

    Thermostatic elements with a built-in sensor should always be arranged horizontally so that the ambient air can freely circulate around the sensor. Do not install them in a vertical position, since the thermal effect on the sensor from the valve body and the heating system pipe will lead to the incorrect functioning of the thermostat.

    Thermostatic elements with a remote sensor

    Thermostatic elements with a remote sensor should be applied if: o Thermal elements are closed with a deaf curtain; o The heat flux from the heating system pipelines affects the built-in temperature sensor; o The thermoelement is located in the draft area; o required vertical installation of thermoelement. The remote sensor of the thermostatic element must be installed on the furniture-free and curtains or on a plinth under the heating device if there are no pipelines of the heating system. When installing the sensor, the capillary tube should be pulled out to the required length (maximum of 2 m) and fasten it on the wall using the accompanying brackets or a special pistol.

    Thermostatic elements of the RAW series

    Thermostatic elements of the RAW series - devices of automatic temperature control, designed to complete the RA radiator thermostators. Radiator thermostat is a proportional direct-acting air temperature regulator with a small proportionality zone, which is currently equipped with systems for the heating of buildings of various purposes. The RA type thermostat consists of two parts: a universal thermostatic element of the RAW series and an adjusting valve with a pre-adjustment of the RA-N bandwidth (for two-pipe heating systems) or Ra-G (for a single-tube system).

    The program of the production of thermostatic elements of the RAW series includes:

  • RAW 5010 is a thermostatic element with an integrated temperature sensor;
  • RAW 5012 is a thermostatic element with a remote temperature sensor;
  • RAW 5110 is a thermostatic element with a built-in sensor and a device 100% overlap of the thermostat valve.

    The thermostatic elements of the RAW series are equipped with system protection devices from freezing, fixing and restricting the temperature setting. RAW 5012 is equipped with an ultra-thin capillary tube with a length of 2 m, which is swept inside the sensor housing and connects a remote sensor with a thermostatic element. In the process of installation, the pipe is pulled into the required length. Clip connection provides simple and accurate mounting of the thermoelement on the valve.

    The technical characteristics of radiator thermostators with thermoelements of the RAW series correspond to European standards EN 215-1 and Russian GOST 30815-2002.

    In order to prevent unauthorized dismantling, the thermoelement can be fixed on the valve using a special retainer (see additional accessories).

    Specifications of thermostatic elements of the RAW series

    The main device of the thermostatic element is a bellows that provides proportional regulation. The thermoelement sensor perceives the change in the ambient temperature. The bellows and the sensor are filled with a special heat sensitive liquid. The adjusted pressure in the bellows corresponds to the temperature of its charging. This pressure is balanced by the power of the tuning springs. When the air temperature is raised around the sensor, the liquid is expanding, and the pressure in the bellows grows. In this case, the bellows increase in the volume by moving the valve spool towards the closure of the heat carrier duct into the heating device until the equilibrium between the spring and the fluid pressure is reached. When the air temperature decreases, the liquid begins to shrink, and the pressure in the bellows decreases, which leads to a decrease in its volume and the movement of the valve spool towards the opening to the position in which the equilibrium of the system will again be established. To eliminate influence warm air From heating nozzle of the heating device, it is recommended to set thermostatic elements, as a rule, in a horizontal position. Otherwise, it is necessary to apply thermoelements with a remote sensor.

    Thermostatically elements of the RAW-K series

    Thermostatic elements of the RAW-K series are automatic temperature controllers with a small proportionality zone. RAW-K are designed to install on the thermostators of the thermostators of HEIMEIER, OVENTROP or MNG, built into the design of steel panel radiators type Biasi, Delta, Dianorm, Diatherm, Ferroli, Henerad, Kaimann, Kermi, Korado, Purmo, Radson, Superia, Stelrad, Veha, Zehnder-Completto Fix. The thermostatic element of the RAW-K series has a liquid sensor with a temperature setting range of 8-28 ° C and is equipped with a device for protecting the heating system from freezing.

    The company "Danfoss" produces 3 modifications of the thermoelements of the RAW-K series:

  • RAW-K 5030 with an integrated temperature sensor;
  • RAW-K 5032 with a remote temperature sensor;
  • RAW-K 5130 with a built-in sensor and a device 100% overlap of the thermostat valve.

    RAW-K 5032 is equipped with an ultra-thin capillary tube with a length of 2 m, which is swept inside the exhaust sensor housing, connecting it with the thermostatic element working bellows. In the process of installation, the tube is pulled into the required length. The thermostatic elements of the RAW-K series comply with European standards EN 215-1 and Russian GOST 30815-2002.

    Electronic radiator thermostat Living Eco

    Electronic radiator thermostat Living ECO® is a programmable microprocessor regulator to maintain a predetermined air temperature, mainly in residential buildings serviced by water heating system. The thermostat is designed to be installed on the closens of radiator thermostators instead of traditional thermostatic elements.

    In Living Eco®, the P0, P1 and P2 programs are installed, which allow you to adjust the temperature in the room at different periods of the day.

    The P0 program supports constant air temperature throughout the day. P1 and P2 programs in order to save energy can reduce the temperature in the room during certain periods of time, which allows to adapt the operation of the heating system to the lifestyle of people living in it.

    The Living ECO® thermostat is supplied with adapters for its installation on Danfoss thermostators, as well as most of other manufacturers. Installing and configuring the Living ECO® thermostat does not represent difficulties, there are only three buttons on its panel.

    Thermostat Living ECO® is equipped with a function open windowwhich turns off the flow of the coolant into the heating device with a sharp decrease in the air temperature in the room, which reduces the loss of heat in the way increases the efficiency of the heating system.

    The main characteristics of the thermostat:

  • ensuring energy saving;
  • ease of installation;
  • simplicity settings;
  • maintaining comfortable temperature;
  • the "open window" function;
  • valve testing function in summer;
  • PID-law of regulation that provides accurate temperature maintenance;
  • adaptive adjustment of the output time after a decrease in temperature;
  • the ability to set different temperatures for weekends and weekdays, as well as up to three periods during the day;
  • long service life of one battery pack (two years);
  • limit limit function (min. / max.) temperature;
  • blocking to protect against children;
  • special mode for a long absence during which the room for a long time not operated;
  • the function of protecting the heating system from freezing;
  • display with background illumination;
  • autonomous food.

    Pre-installed programs

  • The program without an automatic temperature reduction function - supports a permanent arbitrarily set temperature during the day. The energy-saving program - reduces temperature to 17 ° C at night (22.30-06.00). It is possible to change the energy saving program. An extended energy-saving program - reduces temperature to 17 ° C at night (22.30-06.00) and during the daytime on weekdays (08.00-16.00). It is possible to change the extended energy-saving program.

    The function "Long absence" allows to reduce the temperature in the room when it is not operated. The absence period and temperature are adjusted arbitrarily by the consumer.

    The selection of programs and their setup are made in accordance with the instructions attached to the thermoelement.

    TWA thermoelectric actuators

    The thermoelectric mini-actuators of the TWA series are designed for a two-position control of various control valves in heating systems and heat-drying of local ventilation plants.

    The drive is equipped with a visual indicator of the stroke, which shows, in which position is the valve - closed or open.

    TWA actuators depending on the modification can be used with valves of the RA, RAV8 and VMT series manufactured by Danfoss, as well as with HEIMEIER, MNG and OVENTROP valves, having a thread for fastening the drive M 30 x 1.5. In the case of applying a drive with other types of valve valve, the valve must be tested for compatibility of geometry and ensuring its closure. Power supply voltage - 24 or 230 V. Valves can be normally closed in the absence of voltage (NC) and normally open (NO). In addition, the normally closed drive with feed voltage 24 V is supplied with a limit switch (NC / S).

    The thermostat valves with the pre-tuning RA-N and RA-NCX DU \u003d 15 mm (chrome)

    RA-N and RA-NCX regulating valves are assigned to use in two-pipe water heating pumping systems.

    RA-N is equipped with a built-in device for preliminary (mounting) adjusting its bandwidth within the following ranges:

  • Kv \u003d 0.04-0.56 m3 / h - for valves do \u003d 10 mm;
  • Kv \u003d 0.04-0.73 m3 / h - for valves do \u003d 15 mm;
  • Kv \u003d 0.10-1.04 m3 / h - for valves do \u003d 20 and 25 mm.

    Ra-n and Ra-NCX valves can be combined with all the thermostatic elements of the RA, RAW and RAX series, as well as with thermoelectric drive TWA-A.

    To identify RA-N and RA-NCX valves, their protective caps are painted in red. The protective cap should not be used to overlap the coolant flow through the heating device. Therefore, the handle should be applied (code number 013G3300).

    Valve housings are made of pure brass with nickel coating (Ra-N) or chrome (RA-NCX).

    The technical characteristics of the RA-N and RA-NCX valves in combination with thermostatic elements of the RA, RAW and RAX series correspond to European standards EN 215-1 and Russian GOST 30815-2002, and the size of the connecting thread is the HD 1215 standard (BS 6284 1984). All radiator thermostators manufactured by Danfoss are manufactured at factories with ISO 9000 quality certificate (BS 5750).

    To prevent deposits and corrosion, RA-N and RA-NCX thermostat valves should be used in water heating systems, where the coolant meets the requirements of the Rules technical exploitation Electrical stations and networks of the Russian Federation. In other cases, it is necessary to contact the company "Danfoss". It is not recommended to use compositions containing petroleum products (mineral oils) to lubricate the valve parts.

    Setting on the calculated value is made easily and accurately without the use of special tools. To do this, make the following operations:

  • remove the protective cap or thermostatic element;
  • raise the ring settings;
  • rotate the tuning ring scale so that the desired value is opposite the setting mark "O", located on the side of the valve outlet (factory setting "N");
  • release Ring Settings.

    Pre-configuration can be performed in the range from "1" to "7" at intervals of 0.5. The "N" position valve is fully open. Installation should be avoided on a dark zone scale.

    When the thermostatic element is mounted, the pre-tuning is hidden and, thus, protected from an unauthorized change.

    The thermostat valve with a pre-tuning RA-N with a compound fitting

    The RA-N valve is designed for use in two-pipe water heating pump systems with copper or stainless steel pipelines. To connect the valve with a pipeline with a pipeline, special crimping tools are required. Valve Case for appearance and the technical characteristics are identical to the standard valves Ra-N DN \u003d 15 mm. Ra-n can be used with any types of thermal static elements of the RA or RAW series, as well as with thermostatic elements of a special design of type RAX and thermoelectric TWA-A thermoelectric drive.

    The RA-N control valve is equipped with a built-in device for preliminary (monkent) adjusting its KV bandwidth in the range from 0.04 to 0.73 m3 / h.

    To identify valves, the protective cap is painted in red. The cap should not be used to overlap the adjustable medium. To this end, it is necessary to use a special metal handle (code number 013G3300). The valve body is made of nickel-plated brass DZR, and the pressure pin is made of stainless steel. The pin does not require lubrication over the entire life of the valve. The gland seal can be replaced without emptying the pipeline system. Ra-n should be used in water heating systems, where the coolant meets the requirements of the maintenance rules of electrical stations and networks of the Russian Federation. In other cases, it is necessary to contact the company "Danfoss". It is not recommended to use formulations containing oil products (mineral oils) to lubricate the valve parts.

    The thermostat valve with increased bandwidth RA-G

    The valve thermoregulating with increased bandwidth RA-G is designed for use, as a rule, in single-pipe systems of water heating with a pumping circulation of the coolant that meets the requirements of the technical operation of electric stations and thermal networks of the Russian Federation. The valve is not recommended to be used if impurities of mineral oil are present in the coolant.

    RA-G is equipped with a seal that can be replaced without emptying the heating system. The pressure pin in the gland is made of chrome steel and does not require lubrication over the entire life of the valve. All performances of RA-G valves are combined with any thermostatic elements of the RA series.

    Ra-G valves are supplied with gray (for identifying) protective caps that should not be used to overlap the coolant flow. Therefore, a special metal service locking handle should be applied (code number 013G3300).

    A set of X-TRATM thermostatic reinforcement for heated towel rails and design radiators.

    The thermostatic X-TRA ™ kit is specifically designed for heated towel rails. It consists of a valve of the thermostator, the thermostatic element and shut-off valve with drainage function. Innovative self-adhesive connection of valves to the radiator is carried out using a thread one second inches. Valves and thermoelement are available in white, chrome-plated and steel versions, suitable for most heated towel rails. This kit is the perfect ending of the heated towel rail. Attractive and compact design allows you to install the thermostat under the heated towel railway parallel to the wall, eliminating random strikes on it.

    Nomenclature presents two types of thermostators with various principles of regulation:

    • RAX, regulating the room air temperature;
    • RTX, which determines and regulating the temperature of water at the outlet of the heated towel rail. Used on heated towel rails and customizable by 5-10 ° C over temperature indoors, the RTX thermostat provides a constant temperature for drying towels.
    Temperature regulators have the same design with the exception of the number of the setup scales: on RAX - Roman, on RTX - Arabic.

    The valve assembly is a housing with a two-sided self-fitting fitting, which has two sealing rings: one - to compact fitting compound with a heated towel rail, second to seal fitting compound with valve body. The screw with an internal hexagon is used to ensure the sealing of the valve body compound with the fitting. If the sealing rings are not suitable for the fittings of the heated towel rail, the traditional sealing material is used.

  • We recommend to read

    Top