  • Highly efficient, energy-saving ventilation units using heat and moisture recovery from the premises.
  • Possibility to install a filter with a higher degree of purification of the supply air, class F6,F7,F8.
  • The presence of a bypass valve, thanks to which it is possible to naturally cool the air in summer period.
  • Wide the lineup installations from 150 to 2000 m3/h.
  • Reduced power consumption due to DC fans.
  • Low noise level with small dimensions.
  • Possibility to connect an air quality sensor, CO2.
  • Highly efficient heat exchanger with increased permeability and an efficiency of about 90%.
  • Provides a separate, autonomous operation and work in conjunction with air conditioning systems.
  • Lack of condensate drain, and hence the drainage system.
  • Possibility to control the anti-freeze system.
  • The ability to adjust the excess of supply air over exhaust air, up to 20%.

Additional options and accessories

DAIKIN VAM series recuperators are not equipped with frost protection. When operating ventilation units below -10 0 C, it is desirable to install frost protection, which includes:

1. Air heater.
2. Thermostat.
3. Relay.
4. Differential pressure sensor

Installation of an additional air heater is necessary when the structure is operating at temperatures below -10 degrees. Its power is initially calculated for the maximum air flow. If the air flow decreases with a decrease in the temperature outside, the following formula is used to calculate the heater power:

N= -0.33x(T+15)xL


Where: N-heater power, calculated in kW,
T- minimum design temperature for a particular region,
L- air consumption in m3/h.

The heater must be controlled by a capillary thermostat (Shuft NET-5/HY) with an operating temperature range of -30 0 С to +30 0 С, via a solid state relay or a magnetic starter.

ThermostatSolid-state relays
Differential pressure transmitter PS500B
Duct heater
Price: 4200 rub Price: from 1250 rubles. Price: 2100 rubles. Price: from 2500 rubles.

A magnetic starter, unlike a relay, although it has a lower cost, also has a number of disadvantages, one of which is contact noise when the load is turned on and off. To avoid extraneous noise during the operation of the plant heater, it is desirable to install a solid state relay that is completely silent in operation. Just like heaters, relays are selected depending on the power.
If the heat exchanger is planned to be installed in a warm room, then it is advisable to additionally install air dampers at the air inlet and outlet of the unit to the street, which will open when the unit is turned on and close when it is turned off.
In order to be able to connect motorized air dampers to the unit, it is necessary to use a differential pressure sensor, the sensors of which are installed before and after the supply fan. A pressure sensor is also required when a frost protection kit is connected to the system. As a result of the operation of the fan when the unit is switched on, a pressure difference is created and the sensor sends a signal to open the air dampers and to the antifreeze device.
PS500B Operating Instructions

DAIKIN air handling unit control panel

Remote Control air handling unit BRC301B61 allows you to remotely control it, switch operating modes with or without a heat exchanger (relevant in the summer, when the air temperature drops at night and you can cool the room when
outside air), makes it possible to turn on the unit in the FRESH UP mode, when the air supply exceeds its exhaust by 20%, which is very important for normal operation exhaust ventilation in the kitchen, c / a and bathroom. Using the control panel, you can set a timer and adjust the volume of air supplied to the room. The display shows information about the operating mode of the unit, set timers, replacement of dust filters and the need to clean the heat exchange cassette.
The factory fan speed settings can be changed using the service settings. Using the service menu, you can select the maximum and minimum fan speeds out of 14 possible.

Price: 13 900 rubles.

Technical characteristics of recuperators DAIKIN VAM 150-2000

Parameter / Model VAM-150FA VAM-250FA VAM-350FB VAM-500FB
Price Rub 62 600
72 900
83 200
91 900
Air consumption (max) m3/h 150 250
350 500
Power consumption Tue 110 110
210
210
% 85 90 90 90
Noise level (min-max) dB(A) 20 - 27
21- 29 23 - 32 24 - 33
Supply voltage V 220-240 V, 1 phase, 50 Hz
-10 … +40°C, relative humidity max. 80%

Parameter / Model VAM-650 FB VAM-800 FB
VAM-1000 FB
Price Rub 102 600
113 800
127 400
Air consumption (max) m3/h 650 800
1000
Power consumption Tue 260 480
480
Recovery efficiency (max) % 90 90 90
Noise level (min-max) dB(A) 27 - 34
31- 36 31 - 36
Supply voltage V 220-240 V, 1 phase, 50 Hz
Guaranteed outdoor temperature range

Parameter / Model VAM-1500 FB
VAM-2000 FB
Price Rub 141 500
251 200
Air consumption (max) m3/h 1500 2000
Power consumption Tue 900 900
Recovery efficiency (max.) % 90 90
Noise level (min-max) dB(A) 34 - 39 35 - 40
Supply voltage V 220-240 V, 1 phase, 50 Hz
Guaranteed outdoor temperature range -10 … +40°C, relative humidity max. 80%

* - in the complete set of installations with the FB index there is a bypass.

Unit dimensions


36 900 rub.

Daikin ATYN25L/ARYN25L wall mounted air conditioner

With automatic mode. with heating mode. Heating power 2800 W. Noise level 25 dB. With self-diagnosis function. A type indoor unit- wall. . Cooling power 2500 W. With remote control. With auto restart. Coolant - R410A. Served area 25 m 2 . The maximum length of communications is 20 m. The type of air conditioner is split systems. With on/off timer.

buy v online store Ziwo.ru

possible loan

Photo

48 800 rub.

Air conditioner Daikin ATYN25L/ARYN25L Nord-40

With a serviced area of ​​25 m 2 . Auto restart. Auto mode. Fresh air mode. With a noise level of 25 dB. On/off timer. With a heating power of 2800 W. Type of air conditioner - split systems. Type of the internal block - wall. With 2500W cooling power. With a maximum communication length of 20 m. Self-diagnosis. heating mode. Coolant - R410A. Remote control.

buy v online store MirCli.ru

loan possible | pickup possible

Photo

48 800 rub.

Daikin ATYN25L/ARYN25L Nord-40 air conditioner 2.6 kW

Type of the internal block - wall. with heating mode. Noise level 25 dB. With self-diagnosis function. With ventilation mode. Cooling power 2500 W. With remote control. The maximum length of communications is 20 m. Heating power is 2800 W. Type of air conditioner - split systems. Served area 25 m 2 . With auto restart. Coolant - R410A. With on/off timer. With automatic mode.

buy v online store Proclimatgroup.ru

possible loan

Photo

RUB 35,040

Wall-mounted air conditioner Daikin ATYN25L/ARYN25L Nord-30

Fresh air mode. Type of the internal block - wall. heating mode. Self-diagnosis. Auto restart. With a heating power of 2800 W. Type of air conditioner - split systems. Coolant - R410A. With a maximum length of communications of 20 m. With a serviced area of ​​25 m 2. Remote control. With a noise level of 25 dB. On/off timer. Auto mode. With 2500W cooling power.

v online store Ziwo.ru

possible loan

Photo

37 900 rub.

Air conditioner Daikin ATYN25L/ARYN25L

with heating mode. Noise level 25 dB. Heating power 2800 W. With ventilation mode. Cooling power 2500 W. Type of air conditioner - split systems. With auto restart. The maximum length of communications is 20 m. Refrigerant - R410A. With automatic mode. Type of the internal block - wall. With remote control. Served area 25 m 2 . With on/off timer. With self-diagnosis function.

v online store MirCli.ru

loan possible | pickup possible

Photo

47 800 rub.

Daikin ATYN25L/ARYN25L Nord-30 air conditioner 2.6 kW

Type of the internal block - wall. Type of air conditioner - split systems. With a maximum communication length of 20 m. Heating mode. On/off timer. Fresh air mode. Self-diagnosis. With 2500W cooling power. Auto mode. Coolant - R410A. With a heating power of 2800 W. Auto restart. With a serviced area of ​​25 m 2 . With a noise level of 25 dB. Remote control.

v online store Proclimatgroup.ru

possible loan

Photo

35 400 rub.

Wall air conditioner Daikin ATYN25L/ARYN25L Nord-40

With self-diagnosis function. With auto restart. Coolant - R410A. With on/off timer. With remote control. Heating power 2800 W. Cooling power 2500 W. With ventilation mode. Type of air conditioner - split systems. With automatic mode. Served area 25 m 2 . Type of the internal block - wall. The maximum length of communications is 20 m. With heating mode. Noise level 25 dB.

v online store Ziwo.ru

possible loan

Photo

47 800 rub.

Air conditioner Daikin ATYN25L/ARYN25L Nord-30

Remote control. With 2500W cooling power. With a maximum communication length of 20 m. Auto-restart. Type of air conditioner - split systems. With a noise level of 25 dB. Fresh air mode. With a serviced area of ​​25 m 2 . Auto mode. Coolant - R410A. heating mode. Type of the internal block - wall. With a heating power of 2800 W. Self-diagnosis. On/off timer.

v online store MirCli.ru

loan possible | pickup possible

Photo

49 800 rub.

Daikin ATYN35L/ARYN35L Nord-30 air conditioner 3.5kw

The maximum length of communications is 20 m. With self-diagnosis function. Coolant - R410A. Noise level 27 dB. With auto restart. Type of the internal block - wall. With ventilation mode. With automatic mode. Served area 33 m 2 . Cooling power 3300 W. With on/off timer. with heating mode. Heating power 3400 W. With remote control. Type of air conditioner - split systems.

v online store Proclimatgroup.ru

possible loan

Photo

RUB 37,160

Wall-mounted split system Daikin ATYN35L/ARYN35L Nord-30

Type of the internal block - wall. With a serviced area of ​​33 m 2 . Self-diagnosis. Coolant - R410A. heating mode. Auto mode. Fresh air mode. With 3300W cooling power. Remote control. Auto restart. With a heating power of 3400 W. Type of air conditioner - split systems. With a noise level of 27 dB. With a maximum communication length of 20 m. On / off timer.

v online store Ziwo.ru

possible loan

Photo

39 900 rub.

Air conditioner Daikin ATYN35L/ARYN35L

Type of the internal block - wall. The maximum length of communications is 20 m. With heating mode. Heating power 3400 W. Served area 33 m 2 . With ventilation mode. With self-diagnosis function. With remote control. Type of air conditioner - split systems. With auto restart. Coolant - R410A. Noise level 27 dB. Cooling power 3300 W. With automatic mode. With on/off timer.

v online store MirCli.ru

loan possible | pickup possible

Photo

RUB 67,800

Daikin ATYN50L/ARYN50L Nord-40 air conditioner 5kw

With a serviced area of ​​53 m 2 . Type of the internal block - wall. heating mode. Self-diagnosis. Auto restart. Auto mode. Type of air conditioner - split systems. Fresh air mode. With a heating power of 5500 W. With 5300W cooling power. Coolant - R410A. Remote control. With a noise level of 34 dB. With a maximum communication length of 20 m. On / off timer.

v online store Proclimatgroup.ru

possible loan

Photo

39 300 rub.

Wall-mounted split system Daikin ATYN35L/ARYN35L

Country: Japan; Manufacturer: Japan; Warranty: 3 years; INDOOR UNIT: ATYN35L; Cold, kW: 3.3; Heat, kW: 3.47; Consumption during cooling, kW: 1.08; Heating consumption, kW: 1.08; Energy efficiency EER Cooling: 3.06; Energy Efficiency COP Heating: 3.54; Air consumption Cooling, mh: 633; Air consumption Heating, mh: 633; Noise level bl. Cooling, dBA: 27; Noise level bl. Heating, dBa: 27; Max route length elevation difference, m: 20; d pipes of the freon pipeline, : 6.35 9.5; Dimensions

v online store Ziwo.ru

possible loan

Photo

49 800 rub.

Air conditioner Daikin ATYN35L/ARYN35L Nord-30

Type of the internal block - wall. heating mode. With a serviced area of ​​33 m 2 . Self-diagnosis. Auto restart. With a heating power of 3400 W. Fresh air mode. Auto mode. Type of air conditioner - split systems. With a noise level of 27 dB. With 3300W cooling power. Coolant - R410A. Remote control. With a maximum communication length of 20 m. On / off timer.

v online store MirCli.ru

loan possible | pickup possible

Photo

RUB 66,800

Daikin ATYN50L/ARYN50L Nord-30 air conditioner 5kw

Served area 53 m 2 . Type of the internal block - wall. The maximum length of communications is 20 m. With heating mode. Noise level 34 dB. With ventilation mode. Cooling power 5300 W. With self-diagnosis function. With remote control. Heating power 5500 W. Type of air conditioner - split systems. With auto restart. Coolant - R410A. With automatic mode. With on/off timer.

v online store Proclimatgroup.ru

possible loan

Photo

RUB 37,510

Wall-mounted split system Daikin ATYN35L/ARYN35L Nord-40

Country: Japan; Manufacturer: Malaysia; Warranty: 3 years; Cold, kW: 3.30; Heat, kW: 3.47; Consumption during cooling, kW: 1,080; Consumption at heating, kW: 0.980; Energy efficiency EER Cooling: 3.06; Energy Efficiency COP Heating: 3.54; Annual energy consumption, kWh: 540; Air consumption Cooling, mh: 633; Air consumption Heating, mh: 633; Noise level bl. Cooling, dBA: 27; Noise level bl. Heating, dBa: 27; Max track length elevation difference, m: 2010; d freon pipes,

v online store Ziwo.ru

possible loan

Daikin Europe NVis a subsidiary of Daikin Industries Ltd. It is the head office for Europe, Russia, Africa and the Middle East. Funded and supported by a Japanese parent company.

Daikin ( Daikin ) was founded in 1973 (Belgium) due to the growing demand in Europe for quality, reliable air conditioning systems. Initially, it was a small assembly plant, which a short time transformed into the most modern plant for the production of air conditioners in European countries (its area is more than 150.000 sq.m.) It produces products perfectly adapted to the characteristics Russian market. Daikin equipment is supplied to many countries around the world.

PRODUCTS

Daikin Europe NV designs and manufactures high technology domestic and industrial air conditioning equipment, air purifiers and ventilation systems , which take the exhaust air from the room and supply Fresh air from the street.

Daikin ventilation with heat recovery changes the temperature and humidity of the supply air according to the indoor climate. Due to this, a balance is achieved between indoor and outdoor conditions and the load on the air conditioning system is significantly reduced.
Heat Recovery Ventilation (HRV) units can operate independently or together with the entire air conditioning system. The equipment is used in residential, office and commercial premises, sports facilities, as well as restaurants, cafes and other similar facilities.

Advantages of the HRV system

  • can be installed in a false ceiling or in the floor
  • the most compact equipment in its class
  • efficient heat exchanger
  • new model has higher heat exchanger efficiency (latent heat and water vapor removal efficiency)
  • moisture removal
  • twice the moisture absorption rate
  • central and centralized control
  • reduction of heat load on air conditioners by 28%

DAIKIN PRODUCT QUALITY

Daikin equipment stands for energy efficiency, energy savings, ease of placement, environmental friendliness, ease of operation, optimal configuration and compatibility of climate equipment.

The recognized quality of a company's products is determined by special attention which is given to the quality of work performed at all stages of production and after-sales service of Daikin equipment. The quality of products is confirmed by ISO9001 (guarantees product quality) and EUROVENT certificates (members of this organization voluntarily provide their products for testing and evaluation in independent laboratories of the EUROVENT European Quality Assurance Institute - the only independent certification body refrigeration equipment and air conditioners).

Ventilation units with heat recovery

Specifications:

  • Compact and energy saving HRV ventilation system has a wide range of models (9 models with air flow from 150 to 2000 m3/h). This is very good decision for ventilation of apartments and offices.
  • Permissible outdoor air temperature range from -15 °С to +50 °С. The scope of application has been expanded with the possibility of saving energy.
  • Low noise level. The new Multi Arc Blade Fan provides a noise level of 27 dBA (for VAM150FA), which allows you to install a ventilation unit even in bedrooms.
  • More efficient and compact heat exchanger. The latent heat and water vapor transfer rates have been increased, resulting in a 25% reduction in heat exchanger size compared to the previous model.
  • Fresh Up mode eliminates hit unpleasant odors from the toilet and cold air through leaks into the room.
  • Combined operation of air conditioning and ventilation is possible, which increases efficiency climate system and allows you to manage:
  1. joint start or shutdown;
  2. the possibility of ventilation control independent of the air conditioner;
  3. changing the ventilation mode (auto/heat exchange mode/no heat exchange);
  4. indication of filter contamination;
  5. change in air flow rate (high/low);
  6. activating the air pre-treatment function before starting the air conditioner.

*- The sound pressure level is measured in the heat exchange mode.

HRV Plus

Ventilation units with heat recovery, cooling and humidification

Specifications:

  • Humidifier and cooler built into the ventilation unit with heat recovery.
  • Increased free head due to improved fan performance.
  • Heat removal function: the heat accumulated in the room during the day is removed at night.
  • Ventilation units compatible with existing systems Daikin controls.
  • VKM units can only be connected to VRV outdoor units: RXYSQ-P, RXY(H)QP,
  • REY(H)Q-P, RTSYQ-P and RWEYQ-P(R).
  • The ventilation unit control is designed to work together with the indoor units of the VRV system. The VKM installation and the indoor unit are controlled from one remote control.

AHU

Central air conditioners (ventilation)

Due to the variety of configurations and types of execution, flexibility in the selection of equipment, Daikin central air conditioners can be used:

  • in the domestic sector
  • in retail and commercial areas
  • in public and public institutions
  • at industrial and research facilities
  • v food production
  • medicine and pharmaceuticals.

Daikin's standard range of air handling units (D‑AHU) includes 27 standard unit sizes with air capacities ranging from 1,100 to 124,000 m3/h. In addition, it is possible to manufacture according to individual dimensions in increments of 50 mm, and this does not lead to an increase in cost.

In 2011, Daikin launched a new range of units called the Easy AHU. The productivity of new products is from 500 to 30,000 m3/hour. Easy AHU units are structurally simpler and, accordingly, cheaper than standard ones.

energy efficiency

All installations are designed to meet high energy efficiency requirements. When developing equipment, the thermophysical properties of heat exchange surfaces, the efficiency of electric motors, the degree of filtration, insulation, reduction of friction and pressure drops of the air flow are taken into account. The energy efficiency of installations can be further increased by heat recovery.

Efficient air treatment

Depending on the requirements for air purity, central air conditioners are equipped with filters of varying degrees of efficiency:

  • synthetic corrugated
  • flat in aluminum steel mesh
  • compact and soft bag
  • absorption
  • deodorizing

All filters are mounted on commercially available frames with seals.

To prevent dust from entering the air passage when performing Maintenance, the filters are removed from the contaminated side.

The units can be equipped different types and models of humidifiers. Options are available with fully removable humidifiers or with a removable surface evaporation humidifier section.

The units may include heat exchangers with an intermediate coolant or freon, electric heaters, fans, heat recuperators, gas-burners, silencers, controls, automation and security.

D‑AHU units can be combined with chillers and large condensing units, including Daikin inverter condensing units with ozone friendly R‑410A refrigerant.

Variety of designs

The overall dimensions of the central air conditioner can be selected depending on the actual installation conditions. The design is based on a supporting frame and profiles made of aluminum (or anodized aluminum, which is best suited for working in aggressive environments) with a section of 40x40 or 60x60 mm. There are modifications of profiles with a section of 60x60 mm with a thermal insulating insert to reduce heat loss. Profiles with an oval inner surface are recommended for use in food industry, medicine, other areas with special hygiene requirements.

Panels can be flat, 25 and 46 mm thick, or stepped, 42 and 62 mm thick.

Stepped panels allow you to get a flat surface inside the product. Insulation is made of polyurethane foam (40-50 kg/m3) or fibrous mineral wool(90 kg/m3).

Daikin central air conditioners use components produced by companies that are world leaders in their fields: Daikin, Siemens, Belimo, Nicontra, Comefri, Gebhardt.


Modern management

The units are equipped with a control cabinet based on a digital controller with all power and control connections. Upon request, the units can be supplied with sensors, servo drives and protective devices. Along with automation, it is possible to order hydraulic piping elements for water heat exchangers: two- and three-way control valves, pumps, shut-off valves.

Rapid design, installation, commissioning

Daikin VAM-FB– supply and exhaust ventilation unit with heat recovery series HRV, which can be used as part of a multi-zone air conditioning system VRV Daikin. Great option for an apartment country house or office. Supply and exhaust ventilation units HRV corporations Daikin allow you to create ventilation systems with simple and convenient control, with a heat exchange efficiency of up to 80%. The heat exchange unit included in the unit minimizes energy losses in winter period year, transferring the heat of the exhaust air to the cold (supply) air flow.

The Daikin VAM1000F/FA/FB air handling unit with VKM heat recovery performs not only temperature exchange between air flows, but also humidity exchange, and thus “stabilizes” the air in the room. The possibility of air humidification is in many cases a decisive factor when choosing Daikin units.

At the same time, it is possible to avoid excessive dryness of the air in the room, since the special material of the heat exchange unit leaves the room not only warm, but also up to 60% moisture. During the summer season, the installation HRV reduces the heat load on the air conditioning system by an average of 20%. This makes it possible to use air conditioners with a lower cooling capacity for the same rooms.

A single control of air conditioning and ventilation will save a few more percent. Additional energy savings can be achieved by using the "Precool/Heat" mode. Under this mode, the start of the ventilation system is delayed in relation to the operation of the air conditioner, which reduces the time required for cooling / heating the room.

Distinctive features: Compact and energy saving HRV ventilation system has a wide range of models (9 models with air flow from 150 to 2000 m3/h). This is a very good solution for ventilation of apartments and offices.
Permissible outdoor air temperature range from -15 °С to +50 °С. Expanded scope with the possibility of saving energy.
Low noise level. The new Multi Arc Blade Fan provides a noise level of 27 dBA (for VAM150FA), which allows you to install a ventilation unit even in bedrooms
More efficient and compact heat exchanger. The latent heat and water vapor transfer rates have been increased, resulting in a 25% reduction in heat exchanger size compared to the previous model.
The Fresh Up mode eliminates unpleasant odors from the toilet and cold air from entering the room.
Joint operation of the air conditioner and ventilation is possible, which increases the efficiency of the climate system and allows you to control: joint start-up or shutdown; the possibility of ventilation control independent of the air conditioner; changing the ventilation mode (auto/heat exchange mode/no heat exchange); indication of filter contamination; change in air flow rate (high/low); activating the air pre-treatment function before starting the air conditioner.


ventilation unit Daikin HRV has three ventilation modes that can be selected using the remote control remote control installation or remote control of the indoor unit VRV: full heat exchange mode, when the supply and exhaust air exchange heat and moisture; bypass mode, when supply air is directly supplied to the premises, bypassing the heat exchange unit; automatic mode, when the room temperature is automatically selected optimal mode work.

Using a bond paper element ( HEP) and the optimized design of the fan and airflow channels resulted in a very compact unit while maintaining the 28% reduction in air conditioning load achieved by previous models.

The height of the main unit is reduced by 40mm, which makes it easy to install in places with limited space, such as suspended ceilings. Reducing the load on the air conditioning system by an average of 28% (maximum 40%) includes: 20% due to operation in full heat exchange mode (compared to conventional fans) 6% due to automatic changeover of ventilation mode another 2% due to pre-cooling control and heating (reduces the load on the air conditioning system without a running system HRV when the air stays clean certain time after turning on the air conditioner.)

Two speeds can be selected using the installation remote control HRV or indoor unit remote control VRV. Selecting the ventilation mode The remote control can be used to set the ventilation mode, in which the supply of supply air exceeds the exhaust air flow and excludes the possibility of unpleasant odors from the kitchen or toilet entering the room. By changing the remote control settings, you can set the ventilation mode so that the extract air flow is greater than the supply air. In addition to remote control HRV or indoor unit VRV, installation HRV easily integrated into the centralized control system VRVII.

Pre-cooling or pre-heating modes are provided, according to which ventilation is switched on with a certain delay in relation to the moment the air conditioner is started. This significantly improves system efficiency and reduces power consumption.