Series | Type of | Working environment |
52 | normally closed | |
53 | normally closed | water, air, light oil products, diesel fuel |
55 | normally closed | water, air, steam, combustible gas, inert gas |
59 | normally closed | |
61 | normally open | |
62 | normally closed | |
65 | normally open | water, air, steam, gas, light oil products, diesel fuel |
66 | normally closed | water, air, steam, gas, light oil products, diesel fuel |
67 | normally closed | water, air, steam, light oil products |
68 | normally closed | all types of refrigerants except ammonia (NH3) |
83 | normally closed | water, air, inert gas, light oil products |
84 | normally closed | |
85 | normally closed | water, air, light oil products |
88 | normally closed | water, air |
90 | normally closed | steam |
93 | normally closed | water, air, gas, steam, diesel fuel |
95 | normally closed | water, air, oil products, diesel fuel, gas, steam |
99 | normally closed | water, air, light oil products, steam, gas |
* On request, it is possible to supply any CEME valves from the presented model range.
The solenoid valve from the Italian company "CEME" is used in heat and water supply networks, in air conditioning and water treatment systems, in industry and various agricultural production.
Solenoid valves are installed in pipelines, and depending on whether they are closed or open, they block or open the flow for the working medium when the supply voltage is applied to the valve coil.
The control sensor for supplying a signal to close or open a circuit can be various devices eg pressure switch, thermostat, flow switch, float switch and the like.
In the pipeline, the valve can be installed in any position, but the working medium must move in the same direction as indicated by the arrow on the body. The very best and the best option location is coil-up. It is very important that foreign particles are not allowed to enter the valve area. This can have a negative impact.
In addition, the manufacturers indicated that the solenoid valve must not be used for other purposes. For example, you cannot mount it in a structure that was not originally provided for by the developers. It is also forbidden to use the valve in media, the temperature of which is outside the permitted maximum and minimum. Because if it is used in an unintended temperature range, it may fail, resulting in an emergency.
Basic data
NBR is used as a material for the production of membranes. If a different material is required, it is possible to manufacture from FPM-EPDM upon customer request.
The body is cast in brass. Internal parts are made of stainless steel.
The working environment can be a technical or drinking water, light oil products or air. As you can see, solenoid valves can be used almost anywhere.
The electrical connection is a P65 3-pin plug. It is included in the kit.
Rp | D, mm | SKU | Pmin, bar | Rtah, bar | Kv, m3 / h | Dimensions, mm | Weight kg | |||
A | V | WITH | D | |||||||
3/8? | 10 | 8613 | 0,3 | 10 | 1.86 | 61 | 89 | 48 | 77 | 0.54 |
1/2? | 12 | 8614 | 0,3 | 10 | 2.10 | 61 | 89 | 48 | 77 | 0.50 |
3/4? | 20 | 8615 | 0,3 | 10 | 5.70 | 87 | 101 | 69 | 84 | 0.80 |
1? | 25 | 8616 | 0,3 | 10 | 9.60 | 100 | 106 | 80 | 86 | 1.10 |
1?1/4 | 32 | 8617 | 0,3 | 10 | 22.00 | 131 | 122 | 112 | 95 | 2.50 |
1?1/2 | 39 | 8618 | 0,3 | 10 | 27.00 | 146 | 128 | 128 | 98 | 3.00 |
2? | 51 | 8619 | 0,3 | 10 | 35.00 | 174 | 145 | 146 | 108 | 4.60 |
2?1/2 | 65 | 8620 | 0,3 | 10 | 63.00 | 245 | 180 | 184 | 134 | 9.40 |
3? | 75 | 8621 | 0,3 | 10 | 83.00 | 250 | 190 | 184 | 139 | 11.23 |
Rp | D, mm | SKU | Pmin, bar | Rtah, bar | Kv, m3 / h | Dimensions, mm | Weight kg | |||
A | V | WITH | D | |||||||
3/8? | 10 | 8713 | 0,3 | 10 | 1.86 | 61 | 95 | 48 | 83 | 0.60 |
1/2? | 12 | 8714 | 0,3 | 10 | 2.10 | 61 | 95 | 48 | 83 | 0.55 |
3/4? | 20 | 8715 | 0,3 | 10 | 5.70 | 87 | 107 | 69 | 91 | 0.85 |
1? | 25 | 8716 | 0,3 | 10 | 9.60 | 100 | 113 | 80 | 93 | 1.10 |
1?1/4 | 32 | 8717 | 0,3 | 10 | 22.00 | 131 | 128 | 112 | 101 | 2.70 |
1?1/2 | 39 | 8718 | 0,3 | 10 | 27.00 | 146 | 135 | 129 | 105 | 3.00 |
2? | 51 | 8719 | 0,3 | 10 | 35.00 | 174 | 151 | 146 | 114 | 4.50 |
2?1/2 | 65 | 8720 | 0,3 | 10 | 63.00 | 245 | 186 | 184 | 140 | 9.50 |
3? | 75 | 8721 | 0,3 | 10 | 83.00 | 250 | 196 | 184 | 145 | 11.23 |
The voltage is standard, that is, AC ~ 230 Volts and AC ~ 24 Volts, with a frequency of 50 Hz.
If the client needs valves with coils designed for a frequency of 60 Hz or other voltage, then he will have to make an individual order.
Name | vendor code | Voltage | Price |
---|---|---|---|
Solenoid valve n / closed 3/8 "(DN 10) | CEME8613.NBR230 | U = 220V | RUB 3,100 |
Solenoid valve n / closed 1/2 "(DN 15) | SEME8614.NBR230 | U = 220V | RUB 3,100 |
Solenoid valve n / closed 3/4 "(DN 20) | SEME8615.NBR230 | U = 220V | RUB 3,300 |
Solenoid valve n / closed 1 "(DN 25) | SEME8616.NBR230 | U = 220V | RUB 3,300 |
Solenoid valve n / closed 1``1 / 4 (DN 32) | SEME8617.NBR230 | U = 220V | RUB 7,000 |
Solenoid valve n / closed 1``1 / 2 (DN 40) | SEME8618.NBR230 | U = 220V | RUB 7,000 |
Solenoid valve n / closed 2 "(DN 50) | SEME8619.NBR230 | U = 220V | RUB 11 650 |
Solenoid valve n / closed 2``1 / 2 (DN 65) | SEME8620.NBR230 | U = 220V | RUB 27,440 |
Solenoid valve n / closed 3 "(DN 75) | SEME8621.NBR230 | U = 220V | RUB 34 800 |
Coil for n / a closed valve | SEME BDF / R | U = 220V | RUB 500 |
Coil for n / a closed valve | CEME86 | U = 24B | RUB 500 |
Solenoid solenoid valves CEME (Italy) are used in water supply and heat supply networks, in various industries, in water treatment and air conditioning systems. By design, they are divided into normally open- are in the open position when there is no power supply and close when current is applied to the coil, and normally closed valves- are in the closed position when there is no power supply and open when current is applied to the coil. CEME solenoid valves are installed on pipelines and open or shut off the flow of the working medium when the supply voltage enters the valve coil.
The following can be used as a control sensor giving a signal to open or close the power supply circuit of the CEME valve coil:
On the pipeline, solenoid valves are installed in any position (the movement of the working medium must coincide with the arrow indicated on the body). The preferred installation is coil up. It is not allowed to get into the valves of foreign particles, as well as to use it for other purposes.
Rp | D, mm | vendor code | Pmin, bar | Pmax, bar | Kv, m 3 / h | Dimensions, mm | Weight, kg | |||
---|---|---|---|---|---|---|---|---|---|---|
A | V | WITH | D | |||||||
3/8" | 10 | 8613 | 0,3 | 10 | 1,86 | 61 | 89 | 48 | 77 | 0,54 |
1/2" | 15 | 8614 | 0,3 | 10 | 2,1 | 61 | 89 | 48 | 77 | 0,5 |
3/4" | 20 | 8615 | 0,3 | 10 | 5,7 | 87 | 101 | 69 | 84 | 0,8 |
1" | 25 | 8616 | 0,3 | 10 | 9,6 | 100 | 106 | 80 | 86 | 1,1 |
1"1/4 | 32 | 8617 | 0,3 | 10 | 22 | 131 | 122 | 112 | 95 | 2,5 |
1"1/2 | 39 | 8618 | 0,3 | 10 | 27 | 146 | 128 | 128 | 98 | 3 |
2" | 51 | 8619 | 0,3 | 10 | 35 | 174 | 145 | 146 | 108 | 4,6 |
2"1/2 | 65 | 8620 | 0,3 | 10 | 63 | 245 | 180 | 184 | 134 | 9,4 |
3" | 75 | 8621 | 0,3 | 10 | 83 | 250 | 190 | 184 | 139 | 11,23 |
Solenoid valve CEME of pilot action 2/2 way normally closed D25 G1 NBR ~ 1x230V 50Hz art. 8556NN025S CEME
Art. 8556NN250SA57
Classification.
Positions:
- 2- open - closed.
Operating principle:
Important parameters.
Specifications:
Model: 8556NN020S D25 G1 NBR ~ 1x230V 50Hz.
Type: normally closed.
Inlet / outlet pipes: 1 ”.
KV flow rate: 9.6 m3 / h.
The weight:
Materials:
- Body: bronze.
Solenoid valve CEME of pilot action 2/2 way normally closed D20 G3 / 4 NBR ~ 1x230V 50Hz art. 8555NN020S CEME
Art. 8555NN200SA57
Ceme solenoid valves (Italy) are used in water and heat supply networks, in various industries, in water treatment and air conditioning systems, in fountain installations.
Solenoid valves are installed on pipelines in almost any position (coil down is an undesirable option) and, depending on the version, (normally closed or normally open) open or shut off the flow of the working medium when the supply voltage enters the valve coil.
A pressure switch, a float switch, various types of level control devices, a flow switch, a thermostat and the like can be used as a control sensor giving a signal to open or close the power supply circuit of the valve coil.
Classification.
By the number of strokes (channels connecting different contours):
- 2 way - 2 /: one inlet, one outlet.
- 3-way -3 /: one inlet, one outlet and one air outlet, or three ways in various combinations.
Positions:
- 2- open - closed.
- Adjustable position, some models.
Working conditions. This parameter indicates whether the valve is in OPEN (with fluid flow) or CLOSED (without fluid flow) most time.
- N.C. Normally closed: the valve is closed when there is no supply voltage at the coil terminals.
- N.O. Normally open: on the contrary, under the conditions mentioned above, the valve is open.
Operating principle:
Depending on the value of the minimum cut-off pressure (equal to zero or greater than zero), the valves are either direct acting or with a servo drive.
- Direct acting: the medium passage is opened or closed by a sealing piece mounted directly on a plunger with an electromagnet controlled by a coil. Working pressure directly depends on the diameter of the hole and the power of the coil; the minimum working pressure is zero.
- With a servo drive: there are control and main holes, the electromagnetic device opens and closes only the control hole, therefore the maximum and minimum working pressures do not depend on the power of the coil, but only on design features sealing device of the main hole (diaphragm, piston, etc.). For of this type The main characteristic of the valve is the minimum working pressure, which is always non-zero and greater than zero.
Important parameters.
Maximum operating differential pressure (M.R.P.D.), the maximum differential pressure between the valve inlet and outlet at which the solenoid can operate safely. If the outlet pressure is unknown, the value of M.R.P.D. the inlet pressure is assumed.
The minimum operating pressure drop is the pressure required to open (close the valve and hold it open (closed).
Specifications:
Model: 8555NN020S D20 G3 / 4 NBR ~ 1x230V 50Hz.
Operating principle: with a servo drive.
Number of strokes: 2-way.
Type: normally closed.
Working medium: air, water, light oils.
Mounting position: any; the position with the coil down is not recommended.
Minimum operating differential pressure: 0.25 bar.
Maximum operating differential pressure (M.R.P.D.): 10 bar.
Temperature the environment: 80 ° C; in devices direct current at temperatures above 40 ° C, performance characteristics(M.R.P.D.) may decrease.
Maximum temperature working environment: 90 ° C
Inlet / outlet pipes: 3/4 ”.
Flow rate KV: 5.7 m3 / h.
Coil supply voltage: ~ 1x230V 50Hz.
The weight:
Materials:
- Body: bronze.
- Seal: NBR, EPDM-FPM on request.
- Guide rod: stainless steel(has a metal seal with valve body for high temperature service).
- Internal details: stainless steel.
Solenoid valve CEME normally closed D15 G1 / 2 NBR ~ 1x230V 50Hz pilot action 2/2 way art. 8554NN012S CEME
Art. 8554NN120SA57
Ceme solenoid valves (Italy) are used in water and heat supply networks, in various industries, in water treatment and air conditioning systems, in fountain installations.
Solenoid valves are installed on pipelines in almost any position (coil down is an undesirable option) and, depending on the version, (normally closed or normally open) open or shut off the flow of the working medium when the supply voltage enters the valve coil.
A pressure switch, a float switch, various types of level control devices, a flow switch, a thermostat and the like can be used as a control sensor giving a signal to open or close the power supply circuit of the valve coil.
Classification.
By the number of strokes (channels connecting different contours):
- 2 way - 2 /: one inlet, one outlet.
- 3-way -3 /: one inlet, one outlet and one air outlet, or three ways in various combinations.
Positions:
- 2- open - closed.
- Adjustable position, some models.
Working conditions. This parameter indicates whether the valve is in the OPEN (with the flow of the medium) or CLOSED (without the flow of the medium) state the valve is most of the time.
- N.C. Normally closed: the valve is closed when there is no supply voltage at the coil terminals.
- N.O. Normally open: on the contrary, under the conditions mentioned above, the valve is open.
Operating principle:
Depending on the value of the minimum cut-off pressure (equal to zero or greater than zero), the valves are either direct acting or with a servo drive.
- Direct acting: the medium passage is opened or closed by a sealing piece mounted directly on a plunger with an electromagnet controlled by a coil. Working pressure directly depends on the diameter of the hole and the power of the coil; the minimum working pressure is zero.
- With a servo drive: there are control and main holes, the electromagnetic device opens and closes only the control hole, therefore the maximum and minimum operating pressures do not depend on the power of the coil, but only on the design features of the sealing device of the main hole (diaphragm, piston, etc.) ... For this type of valve, the main characteristic is the minimum working pressure, which is always non-zero and greater than zero.
Important parameters.
Maximum operating differential pressure (M.R.P.D.), the maximum differential pressure between the valve inlet and outlet at which the solenoid can operate safely. If the outlet pressure is unknown, the value of M.R.P.D. the inlet pressure is assumed.
The minimum operating pressure drop is the pressure required to open (close the valve and hold it open (closed).
Specifications:
Model: 8554NN012S 15 G1 / 2 NBR ~ 1x230V 50Hz.
Operating principle: with a servo drive.
Number of strokes: 2-way.
Type: normally closed.
Working medium: air, water, light oils.
Mounting position: any; the position with the coil down is not recommended.
Minimum operating differential pressure: 0.25 bar.
Maximum operating differential pressure (M.R.P.D.): 10 bar.
Ambient temperature: 80 ° C; in DC devices at temperatures above 40 ° C, performance (M.R.P.D.) may be degraded.
Maximum working environment temperature: 90 ° C
Inlet / outlet pipes: 1/2 ”.
Flow rate KV: 2.1 m3 / h.
Coil supply voltage: ~ 1x230V 50Hz.
Weight: 0.400 kg
Materials:
- Body: bronze.
- Seal: NBR, EPDM-FPM on request.
- Guide stem: stainless steel (has a metal seal with valve body for high temperature service).
- Internal details: stainless steel.
Solenoid valve D25 G1 "NBR ~ 1x230V 50Hz 2/2 way normally closed art. 8416NN025S C57 CEME
Art. 8416NN250SC57
Ceme solenoid valves (Italy) are used in water and heat supply networks, in various industries, in water treatment and air conditioning systems, in fountain installations.
Solenoid valves are installed on pipelines in almost any position (coil down is an undesirable option) and, depending on the version, (normally closed or normally open) open or shut off the flow of the working medium when the supply voltage enters the valve coil.
A pressure switch, a float switch, various types of level control devices, a flow switch, a thermostat and the like can be used as a control sensor giving a signal to open or close the power supply circuit of the valve coil.
Classification.
By the number of strokes (channels connecting different contours):
- 2 way - 2 /: one inlet, one outlet.
- 3-way -3 /: one inlet, one outlet and one air outlet, or three ways in various combinations.
Positions:
- 2- open - closed.
- Adjustable position, some models.
Working conditions. This parameter indicates whether the valve is in the OPEN (with the flow of the medium) or CLOSED (without the flow of the medium) state the valve is most of the time.
- N.C. Normally closed: the valve is closed when there is no supply voltage at the coil terminals.
- N.O. Normally open: on the contrary, under the conditions mentioned above, the valve is open.
Operating principle:
Depending on the value of the minimum cut-off pressure (equal to zero or greater than zero), the valves are either direct acting or with a servo drive.
- Direct acting: the medium passage is opened or closed by a sealing piece mounted directly on a plunger with an electromagnet controlled by a coil. Working pressure directly depends on the diameter of the hole and the power of the coil; the minimum working pressure is zero.
- With a servo drive: there are control and main holes, the electromagnetic device opens and closes only the control hole, therefore the maximum and minimum operating pressures do not depend on the power of the coil, but only on the design features of the sealing device of the main hole (diaphragm, piston, etc.) ... For this type of valve, the main characteristic is the minimum working pressure, which is always non-zero and greater than zero.
Important parameters.
Maximum operating differential pressure (M.R.P.D.), the maximum differential pressure between the valve inlet and outlet at which the solenoid can operate safely. If the outlet pressure is unknown, the value of M.R.P.D. the inlet pressure is assumed.
The minimum operating pressure drop is the pressure required to open (close the valve and hold it open (closed).
Specifications:
Model: 8416NN025S C57 D25 G1 NBR ~ 1x230V 50Hz
Operating principle: with a servo drive.
Number of strokes: 2-way.
Type: normally closed.
Working medium: air, water, light oils.
Ambient temperature: 80 ° C; in DC devices at temperatures above 40 ° C, performance (M.R.P.D.) may be degraded.
Maximum working environment temperature: 90 ° C
Inlet / outlet pipes: 1 ”.
Flow rate KV: 7.50 m3 / h.
Coil supply voltage: ~ 1x230V 50Hz.
The weight:
Materials:
- Body: bronze.
- Seal: NBR, EPDM-FPM on request.
- Guide stem: stainless steel (has a metal seal with valve body for high temperature service).
- Internal details: stainless steel.
Solenoid valve D20 G3 / 4 "NBR ~ 1x230V 50Hz 2/2 way normally closed art. 8415NN020S C57 CEME
Art. 8415NN200SC57
Ceme solenoid valves (Italy) are used in water and heat supply networks, in various industries, in water treatment and air conditioning systems, in fountain installations.
Solenoid valves are installed on pipelines in almost any position (coil down is an undesirable option) and, depending on the version, (normally closed or normally open) open or shut off the flow of the working medium when the supply voltage enters the valve coil.
A pressure switch, a float switch, various types of level control devices, a flow switch, a thermostat and the like can be used as a control sensor giving a signal to open or close the power supply circuit of the valve coil.
Classification.
By the number of strokes (channels connecting different contours):
- 2 way - 2 /: one inlet, one outlet.
- 3-way -3 /: one inlet, one outlet and one air outlet, or three ways in various combinations.
Positions:
- 2- open - closed.
- Adjustable position, some models.
Working conditions. This parameter indicates whether the valve is in the OPEN (with the flow of the medium) or CLOSED (without the flow of the medium) state the valve is most of the time.
- N.C. Normally closed: the valve is closed when there is no supply voltage at the coil terminals.
- N.O. Normally open: on the contrary, under the conditions mentioned above, the valve is open.
Operating principle:
Depending on the value of the minimum cut-off pressure (equal to zero or greater than zero), the valves are either direct acting or with a servo drive.
- Direct acting: the medium passage is opened or closed by a sealing piece mounted directly on a plunger with an electromagnet controlled by a coil. Working pressure directly depends on the diameter of the hole and the power of the coil; the minimum working pressure is zero.
- With a servo drive: there are control and main holes, the electromagnetic device opens and closes only the control hole, therefore the maximum and minimum operating pressures do not depend on the power of the coil, but only on the design features of the sealing device of the main hole (diaphragm, piston, etc.) ... For this type of valve, the main characteristic is the minimum working pressure, which is always non-zero and greater than zero.
Important parameters.
Maximum operating differential pressure (M.R.P.D.), the maximum differential pressure between the valve inlet and outlet at which the solenoid can operate safely. If the outlet pressure is unknown, the value of M.R.P.D. the inlet pressure is assumed.
The minimum operating pressure drop is the pressure required to open (close the valve and hold it open (closed).
Specifications:
Model: CEME8415NN020S D20 G3 / 4 NBR ~ 1x230V 50Hz.
Operating principle: with a servo drive.
Number of strokes: 2-way.
Type: normally closed.
Working medium: air, water, light oils.
Mounting position: It is recommended to mount the valve with coil in a vertical position. Models 8417, 8418, 8419 should be mounted horizontally with the spool in a vertical position.
Minimum operating pressure drop: 0 bar.
Maximum operating differential pressure (M.R.P.D.): 4 bar.
Ambient temperature: 80 ° C; in DC devices at temperatures above 40 ° C, performance (M.R.P.D.) may be degraded.
Maximum working environment temperature: 130 ° C
Inlet / outlet pipes: 3/4 ”.
Flow rate KV: 5.5 m3 / h.
Coil supply voltage: ~ 1x230V 50Hz.
The weight:
Materials:
- Body: bronze.
- Seal: NBR, EPDM-FPM on request.
- Guide stem: stainless steel (has a metal seal with valve body for high temperature service).
- Internal details: stainless steel.
Solenoid valves occupy a significant part of the company's product range. This Italian company produces more than 20 series of solenoid valves designed to control the flows of transported media of various aggregates and varying degrees of aggressiveness.
Shut-off valves from this manufacturer can be installed in the following systems transportation of liquid and gaseous media:
In Russia, you can buy CEME solenoid valves only from resellers or at the official dealerships of this brand.
Dealers offer a limited assortment, without subsequent purchase support. Moreover, their product may turn out to be a Chinese counterfeit of the original product from Italy. In this case, it does not matter how much the product costs - its operation will cost the buyer much more than the initial expenses.
Official dealers of CEME, such as our online store site, do not dump "in spite of" competitors, but offer more substantial than low prices, Benefits.
What are the benefits of an online store website?