Work electrician secondary circuits. Electrician for switchgears and secondary circuits Electrician for installation of secondary circuits

landscaping 04.03.2020
landscaping

_ 444. Secondary circuit electrician 2nd category

Characteristics of works. Performing the simplest work during the installation of secondary circuits.

Must know: main brands of wires and cables. Assortment of non-ferrous and ferrous metals. The main materials used in the installation of electrical equipment. The main types of fasteners and small structures. The main types of tools used in electrical work. The simplest electrical circuits.

Work examples. Installation and sealing of fasteners (screws, rollers). Removing the upper jute cover of the cable by hand. Production of small fasteners and gaskets that do not require precise dimensions. Coloring of wires and cables.

_ 445. Secondary circuit electrician 3rd category

Characteristics of works. Performing simple installation work on secondary circuits.

Must know: main types of fasteners and structures. The main types of electrical equipment. Types and methods of electrical wiring. Fundamentals of the device of simple devices, electric devices and used electrified and pneumatic tools. Simple electrical circuits. The device and methods of using simple rigging means. Types of welding equipment used in electrical work, and rules for using it.

Work examples. Cable cutting up to 10 kV with temporary termination of the ends. Installation of dowels. Seal of passages for all types of wiring through walls and ceilings. Rolling out wires and cables with the installation of drums. Installation of grounding networks and zeroing devices. Dismantling of simple devices and devices (support insulators, knife switches and switches with a lever drive, fuses, rheostats, current and voltage transformers, etc.). Hole punching with power tools. Installation of junction boxes for cables and wires.

_ 446. Electrician on secondary circuits 4 category

Characteristics of works. Performing work of medium complexity on the installation of secondary circuits.



Must know: bases of the device of the mounted electric equipment. The order of the layout of the reinforcement. Methods for measuring insulation resistance. Electrical circuits of medium complexity. Ways of connecting, terminating and connecting wires and cores of cables of all brands with a cross section of up to 70 mm2. Methods for marking steel and plastic pipes, cables and bends. Rules for slinging and moving equipment. The device and methods of using mechanized rigging equipment. The device of mounting-piston guns, hydraulic and percussion-rotary action tools, rules for their care and use. Purpose of relay protection. The principle of operation and schemes of maximum current protection. Rules for completing materials and equipment for electrical installation work in industrial buildings and engineering structures.

Work examples. Connection, termination and connection of wires, cores of cables of all brands with a cross section of up to 70 mm2, by all means, except for welding. Installation of protective devices, casings and fences. Fastening structures and devices using a mounting piston gun. Soldering or crimping lugs to the cores of cables and wires. Check and adjustment of electromagnetic current and voltage relays. Installation of staples and metal support structures. Fastening structures by gluing. Laying cable trays and perforated mounting profiles. Acquisition of materials and equipment for electrical work in industrial buildings and engineering structures. Installation of steel boxes and strips for laying wires. Installation according to the finished marking of control, measuring and signaling devices that are not equipped with self-recording devices. Marking and connection of wire ends when installing secondary circuits of medium complexity. Installation of terminal blocks, measurement of insulation resistance. Installation of devices such as KSA and their adjustment. Ringing of wires and cables.

_ 447. Electrician on secondary circuits of the 5th category

Characteristics of works. Performing complex work on the installation of secondary circuits.

Must know: electrical circuits of the installed electrical equipment and methods for their verification. Rules for marking the installation sites of supporting structures, equipment and routes for laying wires and cables. Rules for the production of measurements and drawing up sketches of individual wiring assemblies for manufacturing at stands and in workshops. The order of phasing of the completed wiring and methods for checking the completed circuits. Methods for checking control devices, alarms.

Work examples. Laying wires and cables in bundles in boxes, trays and on strings. Installation of all types of terminations for control and special cables. Marking of wires laid between devices and clamps on panels of boards and consoles. Marking the places of installation of measuring instruments, protection and control devices and installation of devices equipped with self-recording devices. Performing measurements and drawing up sketches of individual wiring assemblies for manufacturing on stands and in workshops.

_ 448. Electrician on secondary circuits of the 6th category

Characteristics of works. Performing particularly complex work on the installation of secondary circuits.

Must know: methods of cutting and mounting high-voltage and control cables. Designs of switchboards, consoles, control panels and protection of station nodes. Electrical circuits, methods for checking and regulating electrical equipment. Methods for mounting wires and cables of all brands. Technical characteristics of transformers. The device of electrical installations. Technical conditions for putting objects into operation. Rules for performing work in hazardous areas. General information about relay protection.

Work examples. Marking places for laying wires and cables according to secondary switching schemes. Dialing of the mounted circuit. Installation of couplings on control cables. Preparation of devices and devices for inclusion.

A secondary circuit electrician is a worker who performs the installation and installation of various protective systems, control and alarm systems. When performing work in electrical circuits, it is mandatory to have sufficient qualifications of the worker, as well as an electrician's certificate confirming this qualification. To obtain a certificate, it is enough to be trained as an electrician in secondary circuits at a specialized educational institution of professional additional education - Stroy-Attestate. The Stroy-Attestat MSC training center has been conducting educational activities for more than 9 years, during which thousands of specialists in working and construction specialties have successfully passed certification and are working at their enterprises. We managed to find an approach to our clients so that they can pass certification quickly and comfortably.

Courses for electricians on secondary circuits

This course of study includes training in the form of study you have chosen (full-time or part-time), certification and issuance of documents. When studying in full-time courses, attendance at classes with teachers in classrooms in Moscow is required. When choosing a distance learning method, you only need an Internet connection. Correspondence courses for electricians on secondary circuits are a complete course of theoretical studies that you will pass on your own, without leaving your home and without interrupting your main activity. This training method has already been chosen by many of our customers and were very satisfied, try it yourself!

Electrician's certificate for secondary circuits

After completing the courses, regardless of the chosen form of study, you must pass an attestation of knowledge on the topics studied to confirm your qualifications. If you successfully pass the exam, you will be assigned a category corresponding to the qualification, a certificate of an electrician in the secondary circuits of the established sample, as well as a knowledge test protocol with the points obtained for the exam. All documents are signed by members of the commission and certified by the seal of the Training Center, which confirms their authenticity and validity.

Recertification, knowledge testing

We remind you that the validity of the certificate must be renewed by passing mandatory annual knowledge tests! In the absence of renewal, the certificate is considered invalid after 12 months from the last renewal mark. For all questions related to the training and certification of electricians for secondary circuits, please call the numbers listed in the "Contacts" section, we will be happy to help you!

Unified Tariff and Qualification Directory of Works and Professions of Workers (ETKS), 2019
Issue No. 3 ETKS
The issue was approved by the Order of the Ministry of Health and Social Development of the Russian Federation dated April 6, 2007 N 243
(as amended by: Orders of the Ministry of Health and Social Development of the Russian Federation of November 28, 2008 N 679, of April 30, 2009 N 233)

Electrician for switchgears and secondary circuits

§ 427. Electrician for switchgears and secondary circuits of the 2nd category

Job Description. Installation and sealing of fasteners. Production of small fasteners and gaskets that do not require precise dimensions. Manual driving of earth electrodes. Coloring of wires and tires. Punching nests, holes and furrows according to the finished marking manually. Unpacking the equipment and cleaning up the packing material. Equipment cleaning and wiping. Installation and removal of the applicable scaffolds.

Must know: the main brands of wires used; range of non-ferrous and ferrous metals; types of basic materials used in the manufacture and installation of electrical structures; main types of fasteners and small structures; the main types of tools used in electrical work; electrical diagrams of mounted switchgears and secondary circuits.

§ 428. Electrician for switchgears and secondary circuits of the 3rd category

Job Description. Installation of dowels. Seal of passages for all types of wiring and grounding buses through walls and ceilings. Rolling wires with the installation of drums. Installation of grounding networks and zeroing devices. Equipment coloring. Removal of distribution points (cabinets) of closed or open type. Dismantling of simple devices and devices (support insulators, knife switches and switches with a lever drive, fuses, rheostats, current and voltage transformers, etc.). Hole punching with power tools. Cleaning of welding spots with a mechanized tool. Production of decks and scaffolds. Mounting of busbar holders on supporting columns of insulators. Acquisition of materials and equipment for electrical work in residential, cultural and community and administrative buildings.

Must know: main types of fasteners and fittings; arrangement of applied devices, electric devices and electrified and pneumatic tools; electrical diagrams of mounted devices and circuits; device and methods of using simple rigging means; rules for the acquisition of materials and equipment for performing electrical work in residential, cultural and community and administrative buildings.

§ 429. Electrician for switchgears and secondary circuits of the 4th category

Job Description. Connection, termination and connection of wires of all brands with a cross section of up to 240 mm2 in various ways, except for welding. Installation of protective devices, casings and fences. Marking of laid pipes and bends. Fastening of structures and apparatuses with the help of a powder tool. Crimping tips in the explosion chamber. Soldering ferrules to wire strands. Testing and regulation of electromagnetic current and voltage relays. Installation of staples and metal support structures. Fastening structures by gluing. Measurement of insulation resistance. Laying of steel and plastic pipes in furrows, on floors, on walls, trusses and columns. Laying perforated mounting profiles. Acquisition of materials and equipment for electrical work in industrial buildings and engineering structures. Reinforcement and installation of support insulators, fuses, additional resistances for voltages over 1 kV. Installation of low-resistance shunt resistors. Installation of plates made of insulating materials and protective frames. Installation and preparation for welding of parts of open and shielded busbars (compensators, casings, screens, contact plates, flanges, etc.). Production of oil pipelines. Winding on the transformer tank of the magnetizing winding. Testing of insulators (except for tests in an explosion chamber). Preparation and bending of tires, descents, loops and jumpers. Installation of valves, taps, fittings, pressure gauges and thermometers. Taking oil samples. Assembly of fittings and insulators into insulating hangers for switchgear substations. Filling equipment with oil and draining oil. Revision and installation of valves on pipelines during the installation of transformers. Wire ringing.

Must know: main types of switchgears; methods for measuring insulation resistance; electrical diagrams of mounted switchgears; methods of connecting, terminating and connecting wires of all brands with a cross section of up to 240 mm2; methods of marking steel and plastic pipes and bends; rules for slinging and moving equipment being serviced; device and methods of using mechanized rigging equipment; the device of a powder tool and the rules for caring for it; the device of explosive chambers for pressure testing of tips; purpose of relay protection; methods of mounting switchgears; installation of equipment for drying and pouring oil; arrangement of the main components and parts of transformers; rules for the acquisition of materials and equipment for electrical work in industrial buildings and engineering structures.

§ 430. Electrician for switchgears and secondary circuits of the 5th category

Job Description. Connection, termination and connection of wires of all brands with a cross section of more than 240 mm2 by all methods, except for welding. Installation of disconnectors, separators, short circuiters, grounding switches, arresters and surge arresters with voltage up to 220 kV. Installation of load break switches, boxes with alarm devices and relays and blocking locks. Installation of voltage and current transformers with voltage up to 220 kV. Installation of power transformers, autotransformers and reactors with power up to 63 thousand kVA, voltage up to 220 kV and power up to 125 thousand kVA, voltage up to 110 kV. Testing of insulators in an explosion chamber. Installation of SF6 cells with voltage up to 220 kV. Installation of block transportable devices (UTB). Installation of concrete reactors weighing up to 3 tons. Procurement and installation of main combined and branch busbars, flexible bends and compensators with a cross section of up to 1000 mm2. Installation of ready-made packages and blocks of tires weighing up to 250 kg. Device phasing. Performing measurements and drawing up sketches during the installation of equipment. Testing and installation of radiators. Installation of oil pumps. Installation of busbars from double aluminum channels. Installation of supporting silumin rings on structures. Assembling blind corners of busbars during pre-preparation of blocks. Laying busbars with alignment along the axes and fastening with locks. Installation of equipment for high-frequency communication, protection and telemechanics (except for connection filters and resonant barriers). Installation of installations such as "Dry" and "Hoarfrost". Installation of shielded conductors. Installation of oil switches. Installation of air circuit breakers with voltage up to 110 kV. Mounting of rigid busbars of switchgears. Marking and laying of wires of all grades and sections (except for explosive zones).

Must know: electrical diagrams of the installed equipment; methods of installation, pre-installation inspection, drying and regulation of electrical equipment with voltage up to 220 kV; methods of connecting, terminating and connecting wires of all brands with a cross section of more than 240 mm2; rules for marking the places of installation of supporting structures, equipment, routes for laying wires and tires; rules for making measurements and drawing up sketches of individual wiring assemblies, structures, assemblies and blocks of electrical equipment for manufacturing on stands and in workshops; rules for assembly and fastening of open and shielded busbars; the order of phasing of the completed wiring and methods for checking the completed circuits; isolation characteristics of transformers.

§ 431. Electrician for switchgear and secondary circuits of the 6th category

Job Description. Marking the axes of equipment installation sites. Measurements and drawing up sketches of the installation of individual units of equipment. Installation and regulation of complete switchgear and individual blocks and assemblies. Installation of air circuit breakers, current and voltage transformers, disconnectors, arresters, surge arresters and earthing switches with voltage up to 750 kV. Installation of power transformers, autotransformers and reactors with a capacity of up to 250 thousand kVA, voltage up to 750 kV. Installation of SF6 cells with voltage over 220 kV. Installation of concrete reactors weighing over 3 tons. Installation and revision of complex electrical equipment. Installation of electrical equipment weighing more than 3 tons. Procurement and installation of main, combined and branch busbars, flexible bends and compensators with a cross section of more than 1000 mm2. Installation of ready-made packages and blocks of tires weighing over 250 kg. Installation of resonant barriers and connection filters. Installation of supporting structures for open and shielded busbars. Docking during installation of busbar sections (straight and at an angle). Testing of hydraulic and air drives. Installation of batteries of static capacitors. Assembly and testing of bolted contact connections. Control heating and drying of transformers. Installation of transformer cooling systems. Performing measurements and drawing up sketches for the installation of complex electrical equipment and its individual components.

Must know: electrical circuits; methods of installation, revision and drying of electrical equipment with voltage up to 750 kV and methods of its regulation; methods of installation of wires and cables of all brands; technical characteristics of transformers; arrangement of electrical installations; technical conditions for the commissioning of the installed electrical equipment; rules for performing work in hazardous areas; rules for the implementation of relay protection of mounted equipment.

§ 432. Electrician for switchgears and secondary circuits of the 7th category

Job Description. Installation of power transformers, autotransformers and reactors with a capacity of over 250 thousand kVA and a voltage of over 750 kV. Installation of air circuit breakers, current and voltage transformers, disconnectors and arresters with voltage over 750 kV. Installation and revision of unique electrical equipment. Performing measurements and drawing up sketches for the installation of individual units of unique equipment.

Must know: design and electrical diagrams of the installed equipment; methods of installation, revision and drying of electrical equipment with voltage over 750 kV and methods of its regulation; systems of electric drives of remote control, their device and principle of operation.

Requires secondary vocational education.

\Typical job description for Electrician on secondary circuits of the 4th category

Job description Electrician for secondary circuits of the 4th category

Job title: Electrical installer for secondary circuits of the 4th category
Subdivision: _________________________

1. General Provisions:

    Subordination:
  • The electrician in the secondary circuits of the 4th category is directly subordinated to ..............................
  • The electrician on the secondary circuits of the 4th category follows the instructions .............................................. ............

  • (instructions of these employees are carried out only if they do not contradict the instructions of the immediate supervisor).

    Substitution:

  • The electrician in the secondary circuits of the 4th category replaces .............................................. ................................................
  • Replaces the electrician in the secondary circuits of the 4th category .............................................. ......................................
  • Recruitment and dismissal:
    The electrician for secondary circuits is appointed to the position and dismissed by the head of the department in agreement with the head of the department.

2. Qualification requirements:
    Must know:
  • bases of the device of the mounted electric equipment. The order of the layout of the reinforcement. Methods for measuring insulation resistance. Electrical circuits of medium complexity. Ways of connecting, terminating and connecting wires and cores of cables of all brands with a cross section of up to 70 mm2. Methods for marking steel and plastic pipes, cables and bends. Rules for slinging and moving equipment. The device and methods of using mechanized rigging equipment. The device of mounting-piston guns, hydraulic and percussion-rotary action tools, rules for their care and use. Purpose of relay protection. The principle of operation and schemes of maximum current protection. Rules for completing materials and equipment for electrical installation work in industrial buildings and engineering structures.
3. Job responsibilities:
  • Performing work of medium complexity on the installation of secondary circuits.
page 1 Job description Electrician for secondary circuits
page 2 Job description Electrician for secondary circuits

4. Rights

  • The electrician in the secondary circuits has the right to give instructions to employees subordinate to him, tasks on a range of issues included in his functional duties.
  • The electrician in the secondary circuits has the right to control the fulfillment of production tasks, the timely execution of individual orders by employees subordinate to him.
  • The secondary circuit electrician has the right to request and receive the necessary materials and documents related to the issues of his activities and the activities of his subordinate employees.
  • The secondary circuit electrician has the right to interact with other services of the enterprise on production and other issues that are part of his functional duties.
  • The secondary circuit electrician has the right to get acquainted with the draft decisions of the enterprise management regarding the activities of the Division.
  • The electrician in the secondary circuits has the right to propose for consideration by the manager proposals for improving the work related to the duties provided for in this Job Description.
  • The electrician in the secondary circuits has the right to submit proposals for the consideration of the head of the proposal to encourage distinguished employees, to impose penalties on violators of production and labor discipline.
  • The secondary circuit electrician has the right to report to the manager on all identified violations and shortcomings in connection with the work performed.
5. Responsibility
  • An electrician in secondary circuits is liable for improper performance or non-performance of his duties stipulated by this job description - to the extent determined by the labor legislation of the Russian Federation.
  • The electrician in the secondary circuits is responsible for violating the rules and regulations governing the activities of the enterprise.
  • When transferring to another job or dismissal from the post, the Electrician in the secondary circuits is responsible for the proper and timely handover of cases to the person entering this position, and in the absence of such, to the person replacing him or directly to his supervisor.
  • An electrician in secondary circuits is liable for offenses committed in the course of carrying out his activities - within the limits determined by the current administrative, criminal and civil legislation of the Russian Federation.
  • The electrical installer in the secondary circuits is responsible for causing material damage - within the limits determined by the current labor and civil legislation of the Russian Federation.
  • The secondary circuit installer is responsible for complying with applicable instructions, orders and orders to maintain trade secrets and confidential information.
  • The secondary circuit electrician is responsible for the implementation of internal regulations, safety and fire safety rules.
This job description was developed in accordance with (name, number and date of the document)

Head of structural

The development of the curriculum was carried out taking into account the regulatory documentation for the operation of equipment and safe working conditions:

  • Order of the Ministry of Education and Science of the Russian Federation dated July 1, 2013 No. No. 499 “On Approval of the Procedure for Organization and Implementation of Educational Activities for Additional Professional Programs”;
  • All-Russian classifier of professions for workers, employees, OK 016-94.01.11.2005;
  • GEF by profession of secondary vocational education 270843.04 Electrician of electrical networks and electrical equipment, approved by Order of the Ministry of Education and Science of the Russian Federation dated April 21, 2010 No. 413.
  • Order of the Ministry of Energy of the Russian Federation of January 13, 2003 N 6 "On Approval of the Rules for the Technical Operation of Consumer Electrical Installations".
  • Order of the Ministry of Labor and Social Protection of the Russian Federation of July 24, 2013 N 328n "On approval of the Rules for labor protection during the operation of electrical installations".
  • Decree of the Gosstroy of the Russian Federation of January 8, 2003 N 2 "On the Code of Rules" Labor Safety in Construction. Industry standard instructions for labor protection.

We invite you to study as an electrician in Moscow!

Electrician of electrical networks and electrical equipment - the functions of a qualified specialist include the performance of electrical installation work in residential buildings, industrial, cultural and community buildings, as well as on engineering structures, on construction sites.

Our center provides professional training that will allow you to become a specialist in your field!

Upon completion of the program, you will receive the certificates and certificates required to work as an electrician of electrical networks and electrical equipment.

THE TRAINING PROGRAM IS INTENDED:

  • For students who want to get a profession " electrician of electrical networks and electrical equipment "with assignment of a category;
  • For students who want to independently understand electrical appliances, set up various equipment, know wiring rules.

COST AND SCHEDULE OF CLASSES:

Learning Format Class time Training period Price Nearest date Next recruitment date
Daily (daily) 13:00 - 18:00 2.5 weeks 13 200 rubles set open
Daily (2 times a week) 10:00 - 17:00 (8 hours) 5 weeks 13 200 rubles set open
Evening (3 times a week)

18:00 - 21:00 (4 hours)

6 weeks 13 200 rubles set open
Weekends

10:00 - 16:40 (6 hours)

3 weeks 13 200 rubles set open

AFTER COMPLETING THE TRAINING YOU WILL LEARN:

  • read electrical diagrams;
  • to calculate the characteristics of electrical circuits;
  • Perform all types of electrical wiring work;
  • install lamps of all kinds, various electrical installation products and devices;
  • make various types of wiring connections;
  • check the quality of work performed.

TRAINING PROGRAM:

  • installation of lighting wiring and equipment;
  • installation of cable networks;
  • installation of switchgears and secondary circuits;
  • repair of distribution devices and secondary circuits;
  • repair of lighting networks and equipment.

AT THE END STUDENTS RECEIVE DOCUMENTS:

  • certificate by profession "electrician of electrical networks and electrical equipment" indicating the qualification category.
  • certificate of additional professional training with the assignment of a profession and a qualification category;
  • a copy of the examination protocol.

WHAT ELSE ELECTRIC NETWORKS AND ELECTRICAL EQUIPMENT ELECTRICIAN NEED:

To work at the enterprise, you will also need an electrical safety clearance group. As a rule, an electrician of electrical networks and electrical equipment must have a group of at least III.

We recommend reading

Top