Description Car S2000-M

The car S2000-M is a security and fire control panel designed for use as part of a security and fire alarm system together with the Signal-20, Signal-20P, S2000-4, Signal- 20 "series 02, two-wire line controllers "S2000-KDL", control and fire control devices "S2000-ASPT", relay blocks "S2000-SP1", and "S2000-KPB", keyboards "S2000-K" and " S2000-KS", display units "S2000-BI", access control controllers "S2000-2".

It is the development of the remote control, while maintaining its functions and at the same time having new features.

Additional features:

  • New case with a large liquid crystal display with more information (2 lines of 16 characters). There are functional LED indicators "ALARM", "FIRE", "FAULT", "TROUBLE", displaying the state of the object
  • The number of partitions and alarm loops that can be included in these partitions has increased, which allows you to use this remote control on larger objects
  • Increased the maximum number of user passwords
  • Sections can be combined into groups. This simplifies the group control of arming and disarming. Any section can be included in several groups
  • Possibility to set text names not only for partitions and users, but also for groups of partitions and alarm loops. Text title can be up to 16 characters long
  • Ability to change the names of messages from signaling loops. For each alarm loop added to the console database, 32 custom renaming scripts can be set. Each scenario allows you to set new text names and display type for any 4 standard messages on the device alarm loop
  • The remote control is configured by the "Database Administrator" program from the "Orion Pro" workstation or by the "pprog.exe" utility version 2.00 and higher

Specifications Bolide S2000-M

  • Unit: 1 piece
  • Dimensions (mm): 140x114x25
  • Weight (kg): 0.30
  • The number of devices connected to the RS-485 output - up to 127
  • Number of partitions - up to 511
  • Number of partition groups - up to 128
  • The number of alarm loops that can be combined into sections - up to 2048
  • Number of user passwords up to 2047
  • Number of automatically controlled relay outputs up to 256
  • Number of "entrance zones" - up to 32
  • The volume of the ring buffer of events - up to 1023 messages
  • RS-485 interface line length up to 3000 m
  • The length of the RS-232 interface line for communication with the printer is up to 20 m
  • Power supply - from a redundant DC source (for example, "RIP-12" or "RIP-24"). Supply voltage range - from 10.2 to 28.4 V.
  • Typical current consumption - 70 mA at 12 V supply voltage or 35 mA at 24 V supply voltage
  • Working temperature range - from 0 to +40 °C
  • Weight - no more than 0.3 kg
  • Overall dimensions - 140x114x25 mm

For timely detection and notification of fire in a certain area, fire alarms are installed. Signaling is a complex set of hardware and software. One of the elements of such a combination is the S2000M security and fire control and management panel. The remote control can be integrated into the Orion security system. In addition to the control panel, the system includes 116 more devices and 33 software products. The system has three levels of work construction: lower, middle and high. At the middle level there are control and management panels that provide the implementation of network interaction, event indication and automation control.

general description

The S2000M control panel is an improved successor of the S2000, retaining all the previous features and acquiring new ones. According to numerous user reviews, the S2000-M control and management console is quite easy to use and effectively integrates the functioning of all equipment that is connected to it. The device consumes in normal mode from 10 to 28.4 V voltage.

The console has a modern look, which allows you to use it as efficiently and conveniently as possible. The presence of a hinged control, a keypad and a liquid crystal display with up to 16 characters is an ascetic plus in its accessibility and ease of operation.

Also, the remote control is equipped with light indicators for the notification modes "Fire", "Alarm", "Fault", "Start", "Disabled", Start Delay, Start Canceled, "Automatic Disabled".

The compact case has small dimensions (140 x 114 x 25 mm) and weighs about 300 grams. Remote control is carried out using radio frequency channels.

Additional remote control options

In the S2000M security and fire control panel, in order to use it at very large protection facilities, manufacturers have increased the number of sections and alarm loops, the number of users with a personal access password. The display of system messages on the LCD can be stored in the archive buffer, which has an independent power supply, and later viewed. For the convenience of working with messages, it is possible to set a text description of sections and users directly. Names can be up to 16 characters long.

The name for each saved alarm loop can be used from 32 custom name change scenarios. Each such scenario has the right to set text names and display types for four different messages on the alarm loop of the device.

Electronic capabilities "S2000M"

The option of arming (or disarming) by means of a PIN code is available on the S2000M security and fire control and control panel itself, using special keyboards, Touch Memory keys or Proximity profile cards from devices that have an input for connecting a reader.

More than 30 programs are available, which have a built-in option for auto-control of the outputs of control panels, starting and relay equipment.

There is an additional possibility to connect a printer or a personal computer with the appropriate software for logging events, the status of partitions and alarm loops.

Also provided is the ability to transmit information via GSM cellular communication channels by means of the UO-4S notification transmission system, S2000-PP protocol converter.

Configuration of the S2000M security and fire control panel is done using the software from the Orion Pro AWP package or the pprog.exe service utility version 2.0 or higher.

Technical data of the control panel

The security and fire control panel is characterized by the following parameters:

  • Voltage - consumption in standby mode: 60 mA at 12 V, 35 mA at 24 V; in alarm mode: 80 mA and 45 mA respectively.
  • The clock is powered by a CR 2032 lithium cell with a voltage of 3 V, as well as the power for the save buffer, autonomous operation - more than 5 years.
  • The length of the RS-485 communication line is no more than 3 km.
  • The number of address blocks connected to the RS-485 interface does not exceed 127.
  • The length of the RS-232 communication line - does not exceed 20 m.
  • The number of alarm loops, control circuits, addressable detectors and other controlled elements - no more than 2048.
  • The number of relays of address blocks - no more than 256.
  • The set of groups of elements - no more than 511, groups of sections - up to 128.
  • The number of information notices in the offline log is about 8000. If the number limit is exceeded, new messages are written in place of the last one in the order they were received.
  • The number of registered users is no more than 2047. Of these, the number of keys with administrative rights is 1, the number of user codes is 2046. The number of access levels is 255, including 252 with custom rights.
  • The length of text names, zones and users is 16 characters.

Scope of application

The S2000M fire and security monitoring and control panel functions as efficiently as possible in retail and warehouse premises, hospitals, work offices, entertainment centers, catering facilities (restaurants, cafes), residential buildings and apartments.

The fire station combines a lot of specialized equipment in the information sphere to create a common control center. At the same time, all incoming data is systematized and controlled.

The remote control itself must be located in a protected area, and must also be protected from the negative effects of atmospheric influences and mechanical damage.

The device is designed for continuous round-the-clock operation. Operating functional parameters are limited by ambient temperature from -10 to +55 degrees Celsius, relative air humidity up to 93% in the absence of wet condensate.

Projects with the use of "S2000M"

The S2000M device, as a part, has a wide range of integration into buildings of various configurations. Projects with the use of the control and management console are distinguished by well-thought-out safety and implementation efficiency.

In one of the projects of the medical center, a fire alarm system, a warning system and a medical center control system were introduced. The protected area was 324.02 m 2 . For visual control of notices, the RS-485 interface of the S2000M security console was used.

In the project of the central distribution warehouse of the Moscow region with the presence of the S2000M console, it was integrated into the ready-made APS of the warehouse. Escape routes, arrangement of smoke exhaust valves and other elements were developed taking into account the introduction of this security and fire control panel.

The control panel S2000M is one of the main devices used in the construction of fire safety systems based on ISO "Orion". It connects all system devices via RS-485, receives signals, controls, displays all system information on the display and writes it to the event log, and much more.

According to the structure, all ISO "Orion" devices are divided into 3 levels. S200M is located on the second, since it performs the functions of coordinating the upper software and lower hardware levels, as well as organizing network interaction between them. Simply put, the device receives signals from the lower level, processes them and transfers them to the upper level, and vice versa.

ISO "Orion" levels

On the basis of the S200-M control panel, it is possible to build systems of varying complexity and configuration, some of which we will consider below.

In this case, S2000M allows you to combine several separate systems into a single network with their own monitoring and control devices, which makes it possible to monitor and control each of the systems from a single dispatch center or fire station. Since the devices are connected via the RS-485 interface, they can be located at a considerable distance from each other. For greater clarity, the system also uses an indication block that displays all changes and events in the systems, as well as a control and indication block that allows remote control of zones and partitions. All these actions are controlled by the C 2000M remote control.

In addition, the console can be used when it is necessary to expand existing systems, when one control panel is no longer enough, or when additional units need to be connected.

Such a system is built using the Signal-10 addressable-threshold control panel, combined with the S2000M console and the rest of the system units via the RS-485 interface. The remote control performs all of the above functions, and also allows arming/disarming address-threshold loops of the Signal-10 control panel.

The address-analogue system is the most complex and functional, since it allows you to determine the location of the alarm with an accuracy of the detector. In this case, the S2000M interacts with the S200-KDL controller, as well as organizing the communication of all system devices via RS-485 and its transmission to the Orion/Orion-Pro workstation.

Interaction of the S2000M with the Orion or Orion Pro workstation is possible in 2 modes:

1. Computer mode

This mode assumes the joint operation of the S2000M remote control and a PC. The remote control is always on and polls all devices in the system, while the PC only polls the remote control for information. The main advantages of this mode are the ability to freely control devices from the remote control when the PC is turned on, the absence of control switching between the PC and the remote control, as well as unloading the PC due to the performance of many functions by the S2000M remote control.

2. PI/Reserve mode

This mode assumes constant control of the system devices using a PC. At the same time, the S2000M console is in reserve and comes into operation when the PC is turned off. After the restoration of the work of the Orion workstation, the console switches back to the standby mode. This control method is used quite rarely and is not recommended for use in security and fire protection systems. It can be used exclusively in cases where the functionality of the workstation is limited by the remote control, or for old versions of the Orion workstation that do not support the "Computer" mode.

Scheme of connection of the control panel S2000M

Remote control and management with a two-line LCD indicator, the number of sections - 511, loops (zones) -2048 (S2000M / C2000M remote control)

The S2000M security and fire control panel (hereinafter referred to as the control panel) is designed to work as part of an addressable fire and security alarm system and control fire fighting equipment. Together with the Orion ISO devices, it can perform the functions of a block-modular security and fire alarm control device, a control device for light, sound and voice warning, gas, powder aerosol and water fire extinguishing, smoke protection, building engineering systems. The information interaction of the blocks is carried out via a wired communication line RS485. The functions of the device can be expanded by connecting additional blocks.

Key Features:

  • Indication of the modes "Alarm", "Fire", "Start", "Stop", "Fault", "Disabled". The ability to view individual zones (sections) and system elements that have these states, with display on a symbolic indicator. Sound signaling of alarms, fires, starts and malfunctions on the built-in sound signaling device. Indication of the status of security zones, fire fighting equipment and other actuators on the blocks "S2000-BI", "S2000-BKI", "S2000-PT", "Potok-BKI"
  • Automatic control of means of light and sound notification, smoke protection, engineering equipment, signal transmission outputs "Alarm", "Fire", "Start" and "Fault" using control-start and signal-start blocks, receiving-control blocks. Automatic start and stop of devices of the voice notification of the Rupor series. Automatic control of operating modes of the access control and management subsystem to unblock escape routes in case of fire.
  • Manual control from the keyboard of the remote control and display units:
  • management of security and fire alarm modes: arming, disarming, resetting alarms, disabling detectors and actuators (only those controlled by the remote control);
  • manual start and stop of light, sound and voice warning, smoke protection, engineering equipment;
  • control of "S2000-ASPT" devices using "S2000-PT" blocks: manual start and stop of the fire extinguishing installation, suspension of the start delay and immediate start without delay, selection of automatic or manual control mode of the fire extinguishing installation, alarm reset;
  • control of Potok-3N devices using Potok-BKI blocks: manual start and stop of the fire extinguishing installation, selection of automatic or manual control mode of the installation
  • Possibility of connection to AWP "Orion Pro" to expand the possibilities of monitoring the state of the protected object and control
  • Possibility of transmitting notifications to the security console using communication blocks "S2000-IT", "UO-4S", "S2000-PGE" and "S2000-PP". Possibility to connect the ATS100 radio transmitter of the LARS radio security system, RS-202TD of the "Reef String 202" ("LONTA 202") or TRX-150 radio security system for transmitting notifications via radio channel
  • Event log with the ability to view it on the remote control screen and print on a printer with a serial RS-232 interface
  • Configuring the remote control in the program "Pprog.exe"

Specifications:

PARAMETER NAME

PARAMETER VALUE

Number of devices and devices ISO "Orion" connected to the RS-485 line, not more than

RS-485 interface

Communication line length RS-485, no more

RS-232 interface

Number of devices connected to the RS-232 output

1
(computer with workstation, printer, ATS100 or TRX-150 radio transmitter (via converter) or RS-202TD radio transmitter)

Communication line length RS-232, no more

Number of alarm loops and addressable detectors grouped into sections, no more than

Number of relay outputs controlled in automatic mode, no more

Number of sections, no more

Number of partition groups, no more

Number of user passwords, no more

Event log size

Liquid crystal display

2 lines x 16 characters, backlit

from a redundant DC source

Supply voltage

10.2 to 28.4 V

Average current consumption in standby mode

at supply voltage 12 V

at 24 V supply voltage

Maximum current consumption in alarm mode

at supply voltage 12 V

at 24 V supply voltage

Working temperature range

from minus 10 to +55 °C

Degree of protection of the shell

IP30 (when wall mounted)

Weight, no more

dimensions

140x114x25 mm

Type of connection to the device

screw terminal block, wire from 0.2 to 1.5 sq. mm

Mounting method

wall mounted

Equipment Consulting New question

Ask a specialist about S2000M control panel with a two-line LCD indicator

Question from: evgeny

hello what version of remotes do you provide?

  • Answered: Kuzmin Boris Hello. 4.12
  • S2000-ASPT fire extinguishing control device, Potok-3N water fire extinguishing station control device, S2000-KPB and S2000-SP1 relay modules, Rupor voice alarm device, system status indication units: S2000-BKI, S2000-BI, S2000-PT and S2000-BI version 01, devices for transmitting notifications via the S2000-IT telephone line and the UO Orion GSM channel, the S2000-2 access controller, additional remote keyboards S2000K and S2000-KS, as well as in the ISO AWP system "ORION" and "Orion Pro".

    Addressable receiving and control panels of the S2000 series (analogue and addressable alarm loops) have stable characteristics, and belong to the "Universal alarm systems" category.

    Control of up to 127 devices (Bolid address system) connected to the console via the RS-485 interface;

    Display on the LCD (liquid crystal) indicator of events occurring in the system;

    Storage in a non-volatile buffer of events with the ability to view on the display and print them on a printer with a serial interface RS-232;

    Signaling alarms and events with a built-in sound signaling device;

    Management of taking / removing and monitoring the status of alarm loops from the remote control;

    Programming the configuration parameters of devices, printing the configuration on a printer, setting the addresses of devices and addressable devices;

    Restricting access to control and programming functions using passwords.


    Specifications S2000M (Bolid)

    PARAMETER NAME PARAMETER VALUE
    Number of devices and devices ISO "Orion" connected to the RS-485 line, not more than
    RS-485 interface 1
    Communication line length RS-485, no more 3000 m
    RS-232 interface 1
    Number of devices connected to the RS-232 output

    1
    (computer with workstation, printer, ATS100 or TRX-150 radio transmitter (via converter) or RS-202TD radio transmitter)

    Communication line length RS-232, no more 20 m
    Number of alarm loops and addressable detectors grouped into sections, no more than 2048
    Number of relay outputs controlled in automatic mode, no more 256
    Number of sections, no more 511
    Number of partition groups, no more 128
    Number of user passwords, no more 2047
    Overvoltage protection 2 steps
    Event log size 8000
    Liquid crystal display 2 lines x 16 characters, backlit
    Food from a redundant DC source
    Supply voltage 10.2 to 28.4 V
    Average current consumption in standby mode at a supply voltage of 12 V / 24 V 60 mA / 35 mA
    Maximum current consumption in alarm mode at a supply voltage of 12 V / 24 V 120 mA / 65 mA
    Working temperature range from minus 10 to +55 °C
    Degree of protection of the shell IP30 (when wall mounted)
    Weight, no more 0.3 kg
    dimensions 140x114x25 mm
    Type of connection to the device screw terminal block, wire from 0.2 to 1.5 sq. mm
    Mounting method wall mounted

    The full list of functions of the fire and security fire control panel Bolid S2000M:

    Possibility to combine individual OPS loops into sections, while supporting a larger number of loops than the previous S2000 analogue, which allows it to be used on especially large objects;

    Displaying text titles on a large LCD, sections and user names in the event log. The length of the display line is 32 characters. Now it is possible to set a textual description of users, partition groups, partitions and alarm loops;

    Increased maximum number of system users (PIN and TouchMemory);

    Sections can be combined into section groups. This allows group control of arming and disarming. Any group can include any section of the system;

    Controlling the arming, dismounting and monitoring of the status of system sections, both from the console and from the S2000-K keyboard, the S2000-KS console and the S2000-4 device. At the same time, the control powers are delimited by passwords (the control rights for arming/removing partitions are set for users and separately for each connected device).

    Possibility of software automatic control of relay outputs of relay blocks S2000-SP1, S2000-SP2 and S2000-KPB linked to the state of partitions. Possibility to control the outputs of devices S2000-4, Signal-20P and Signal-20 series 02. and other ISO Orion devices. Possibility to control relay outputs with preset delay time;

    Control of the display of partition states on the S2000-BI and S2000-BKI display units (and other display units);

    The S2000M console transmits (duplicates) the events occurring in the system to the S2000-K keyboards for their display on the indicator and the S2000-IT information transmission device (informer);

    For convenient logging of events and displaying the status of sections and loops of the security and fire alarm, the control and management panel can be connected to a personal computer with the software AWP "Orion Pro";

    Also, in the "programming" mode, the remote control can perform the function of an interface converter RS ​​232 - RS 485. This function allows you to configure the remote control and devices connected to it of the Bolid address system;

    The console has the ability to connect several subsystems of the fire and security alarm system based on the S2000M console to a personal computer with the Orion workstation;

    S2000M, when disconnected from the PC, switches to offline mode and continues to work with the specified configurations;

    Programming and configuration of the S2000M control and management console is carried out using the program (utility) "pprog.exe" or the "Database Administrator" program from the "Orion Pro" workstation, which can be downloaded on the official website of the Bolid company, or on the website of the company "ABars" in the "Documentation" section (there you will also find the connection diagram and the passport of this network controller).

    A wide range of devices for fire alarms of the BOLID brand allows you to choose a model for any request and functionality. A large selection will delight companies involved in the installation of fire and security alarm systems and their customers.

    Although the S2000M belongs to the category " inexpensive remote controls", it is reliable, like all other elements of the Bolid trademark.

    Office alarm;
    Security and fire alarms for cafes and clubs;
    Alarm to the store;
    Security systems for warehouse and service premises;
    Autonomous alarm system for an apartment, house or cottage;
    Fire alarms for covered parking lots, garages and parking lots;
    Comprehensive protection for state institutions (kindergartens, schools, other educational institutions)

    When choosing, pay special attention to a careful study of the technical characteristics, the choice of suitable security detectors, fire detectors, special cable products. Devices of the S2000 line are among the best in terms of price-quality ratio and are recommended for use in a wide range of fire and security alarm systems. All control panels (PKP) of this brand have the ability to operate with most of the backup power sources presented on this site.

    S2000M analogues and other devices similar in characteristics: S2000

    Buy and order delivery of fire alarm systems in Moscow:

    You can order and buy the S2000M remote control, as well as other Bolid products (their analogues, detectors, relays) through the fire alarm online store of our website or order delivery and professional installation services at your premises in Moscow from the ABars company. (Attention, delivery is free of charge for orders over 60 thousand rubles).

    We recommend reading

    Top