Passport for a fireproof wooden door. Fire door EI60 - Zodchiy Company - g

The buildings 20.06.2020
The buildings

Passport for a fire door has been a mandatory operational document since 2006, based on GOST 2.601-2006. Up to this point, certification of PD was not mandatory.

According to GOST, a product passport is compiled when there is no need to enter additional information about its operation and / or confirm such information (repair, maintenance, etc.).

Fire doors are just products of this type, therefore, in the vast majority of cases, only a passport is mandatory for PD.

Although PD manufacturers, if necessary, can use other mandatory operational documents, such as:

  • Form - make up when it is necessary to enter additional information about the operation of the product, repair and / or data on maintenance;
  • Label - compiled for products for which the operating data does not exceed six main points, and when it is not necessary (or technically impossible) to enter additional information on the operation;
  • A list of operational documents is compiled when the set of documents for the product includes more than two separate (independent) operational documents.

It is important to remember that, depending on the purpose of certain structures, the conditions of use and the amount of data necessary for their correct operation, it is mandatory to draw up either a passport, or a form, or a label, or one of these documents is included in the combined operational document.

Key Points

For each manufacturer of refractory structures, these items may differ, supplemented and changed over time, however, as a rule, the most significant sections of the passport on the door are almost the same for all manufacturers.

1. Basic product information:

  • Purpose of the product (where the PD is installed, in what types of buildings and for what purpose);
  • Fire safety compliance certificate (indicating the certificate number);
  • Other certificates if available (for soundproofing, smoke and gas tightness, etc.).

2.Main Specifications:

  • Overall dimensions - width, height;
  • Finishing material of the door frame and leaf - metal, wood or glass;
  • Color;
  • Double-field or single-field;
  • Deaf or with glazing;
  • Number of opening-closing cycles;
  • Limit of fire resistance, smoke and gas tightness;
  • Certificates of conformity - detailed information (number, validity period, by whom issued) and other conditions.

3. Completeness:

  • Complete set of doors in pieces - leaf, frame, glazing, lock, door closer, hinges, RPZ, ventilation grille, thresholds, etc.;
  • Complete set of documents in pieces - a copy of the certificate of conformity; a copy of the sanitary and epidemiological conclusion; passport and other documents.

4. Security measures:

  • Measures to ensure the safe operation of the product;
  • Measures to ensure the safe installation of the structure;
  • Prohibitions and restrictions on the use of the door and other conditions.

5. Storage and transportation:

  • General conditions of storage and transportation;
  • Conditions of transportation by various modes of transport by road, rail and sea;
  • Conditions of product packaging during transportation and storage;
  • Safety during storage and transportation of doors and more.

6. Instructions for installation and operation

This section of the passport describes in detail the technology for installing fire doors and the essential conditions for their operation.

7. Warranty obligations:

  • General conditions of the seller's guarantee for doors and the essential conditions for their implementation;
  • Warranty period in months and/or years, as well as opening-closing cycles;
  • An indication of what exactly the manufacturer's warranty covers (as a rule, the warranty does not apply to door fittings - door closer, lock, handles, hinges and other elements);
  • Conditions when the warranty on the door is canceled (mechanical damage due to the fault of the customer, non-observance of the operating conditions by the customer, etc.).

8. Acceptance certificate:

  • The name of the door is deaf, with glazing, double-sided or single-sided;
  • Factory number;
  • Release date;
  • Mandatory mark of the quality control department - the signature of the controller, the stamp of the manufacturer.

Fire doors steel deaf single-leaf

Always in stock, standard sizes 2070mm*870mm and 2070mm*970mm

Depending on the purpose and requirements, fireproof metal doors can be divided into 3 types:

With glazing less than 25% of the door area

With glazing over 25% of the door area

The door provided above belongs to the first type - a single-leaf steel deaf fire door

According to GOST R 53307-2009 Building structures, FIRE DOORS AND GATES, Fire test method, paragraph 5: the following 2 limit state indicators apply to fire doors:

Loss of integrity (E)

Loss of thermal insulation capacity (I)

Our company manufactures solid steel fire doors with the following fire resistance limits:

DPM EI-15 (with a fire resistance limit of 15 minutes)

DPM EI-30 (with a fire resistance limit of 30 minutes)

DPM EI-45 (with a fire resistance limit of 45 minutes)

DPM EI-60 (with a fire resistance limit of 60 minutes)

Fire resistance limits of fire barriers according to the "Technical Regulations on Fire Safety Requirements" (Federal Law of July 22, 2008 No. 123-FZ), table 23:

Type of fire barriers 2 - fire resistance limit of fire barriers REI45, type of filling openings in fire barriers 2, type of tambour-lock 2

2. Partitions:

Type of fire barriers 1 - fire resistance limit of fire barriers EI45, type of filling openings in fire barriers 2, type of vestibule-lock 1.

Type of fire barriers 2 - fire resistance limit of fire barriers EI15, type of filling openings in fire barriers 3, type of vestibule-lock 2.

3. Translucent partitions with a glazing area of ​​more than 25 percent:

Type of fire barriers 1 - fire resistance limit of fire barriers EIW45, type of filling openings in fire barriers 2, type of vestibule-lock 1.

Type of fire barriers 2 - fire resistance limit of fire barriers EIW15, type of filling openings in fire barriers 3, type of vestibule-lock 2.

4. Overlays:

Type of fire barriers 1 - fire resistance limit of fire barriers REI150, type of filling openings in fire barriers 1, type of tambour-lock 1.

Type of fire barriers 2 - fire resistance limit of fire barriers REI60, type of filling openings in fire barriers 2, type of vestibule-lock 1

Type of fire barriers 3 - fire resistance limit of fire barriers REI45, type of filling openings in fire barriers 2, type of vestibule-gateway 1.

Type of fire barriers 4 - fire resistance limit of fire barriers REI15, type of filling openings in fire barriers 3, type of vestibule-lock 2

Fire resistance limits for filling openings in fire barriers according to the "Technical Regulations on Fire Safety Requirements" (Federal Law of July 22, 2008 No. 123-FZ), table 24:

1. Doors (excluding doors with more than 25 percent glass and smoke and gas tight doors), gates, hatches, valves, curtains and screens:

Type of filling openings in fire barriers 2 - fire resistance limit EI30

Type of filling openings in fire barriers 3 - fire resistance limit EI15

2. Doors with more than 25 percent glazing:

Type of filling openings in fire barriers 1 - fire resistance limit EIW60

Type of filling openings in fire barriers 2 - fire resistance limit EIW30

Type of filling openings in fire barriers 3 - fire resistance limit EIW15

3. Smoke and gas tight doors (except for doors with more than 25 percent glass):

Type of filling openings in fire barriers 1 - fire resistance limit EIS60

Type of filling openings in fire barriers 2 - fire resistance limit EIS30

Type of filling openings in fire barriers 3 - fire resistance limit EIS15

4. Smoke and gas tight doors with more than 25 percent glazing, curtains and screens:

Type of filling openings in fire barriers 1 - fire resistance limit EIWS60

Type of filling openings in fire barriers 2 - fire resistance limit EIWS30

Type of filling openings in fire barriers 3 - fire resistance limit EIWS15

5. Elevator shaft doors:

Type of filling openings in fire barriers 2 - fire resistance limit EI30 (in buildings with a height of not more than 28 meters, the fire resistance limit of elevator shaft doors is taken as E 30)

Type of filling openings in fire barriers 1 - fire resistance limit E60

Type of filling openings in fire barriers 2 - fire resistance limit E30

Type of filling openings in fire barriers 3 - fire resistance limit E15

7. Curtains:

Type of filling openings in fire barriers 1 - fire resistance limit EI60

Requirements for the elements of the vestibule-lock according to the "Technical Regulations on Fire Safety Requirements" (Federal Law of July 22, 2008 No. 123-FZ), table 25:

1. Type of vestibule-gateway 1:

Types of vestibule-lock elements - partitions 1, ceilings 3, filling of openings 2

2. Type of vestibule-gateway 2:

Types of elements of the vestibule-gateway - partitions 2, ceilings 4, filling openings 3

Our company is engaged in the manufacture and installation of steel deaf single-leaf fire doors. It is clear that the information described above is difficult to understand and, so that you do not make mistakes when choosing and calculating such structures, we will be happy to consult with you and select the best option based on your project or prescription.

Each fire door, mandatory when selling, must be accompanied by a “Passport for a fire door”. It may be required by the fire inspector when accepting an already installed door. In the absence of a passport, the door may not be accepted.

Each manufacturer develops its own passport. Here is the passport we provide.

FIRE DOORS

THE PASSPORT

1. GENERAL INFORMATION ABOUT THE PRODUCT

Doors are designed for installation ** in specialized premises requiring protection from fire factors and unauthorized entry.

Fire safety certificate _________________________

Doors are available in spirit options:

- blind door (without glazing) - DP

– glazed door (glazing up to 25% of the area of ​​the traffic police leaf

The manufacturer reserves the right to make changes in the design of the door that are not specified in this passport, without deteriorating its fire resistance.

At the request of the Customer, it is possible to change the overall dimensions of the door for a ready mounting opening and install additional locks.

Note:

** The installation location of the fire door unit must comply with SNiP 21-01-97* or GOST R 53780-2010

4. SAFETY PRECAUTIONS

4.1. Guide the door leaf smoothly to avoid injury to yourself and door breakage.

4.2. Do not close the door by holding it by the end.

4.3. Do not leave things and tools within the turning radius of the door leaf.

4.4. Do not leave people closed in the room where the door is installed.

4.5. Allow only people who are familiar with the passport for the product and trained to work with the lock to operate the door.

5. STORAGE, TRANSPORTATION, PACKAGING

5.1. Before commissioning, the product must be stored in the manufacturer's warehouse at an ambient temperature of 5 to 40°C and a relative humidity of not more than 80% at a temperature of (25±10)°C.

5.2. When storing products in a stack, their number in height should not exceed three.

5.3. Keys and passports must be stored separately from the doors with the number of keys on the door tag.

5.4. The product can be transported by all means of transport in accordance with the "Rules for the carriage of goods" in force for each type of transport.

During transportation, it is not allowed:

— impact of direct precipitation (rain, snow);

- ingress of construction dirt onto the canvas, especially cement dust or mortar;

- deformation of the door frame and mechanism during rigging.

6. WARRANTY

6.1. The manufacturer guarantees the quality of the door (and its elements) subject to the installation requirements, operating conditions, rules of transportation and storage.

6.2. Warranty period (excluding door closers) is 1 year from the date of sale.

6.3. During the warranty period, the manufacturer undertakes to repair the failed parts or the product as a whole free of charge, provided that the defective parts or the product are returned with a passport.

6.4. In case of failure of the product through the fault of the Customer, the manufacturer can repair it at the expense of the Customer.

7. ACCEPTANCE CERTIFICATE

Door manager No.______ meets specifications

TU 5262-005-20504122-2014 and recognized as serviceable.

Release date "______"__ 2014

OTK mark_______ (signature) M.P.

Date of sale "______"__ 2014

Any fire gates must first of all satisfy the basic requirement, to withstand the impact of the flame for a strictly limited period of time. The result is achieved by a feature; in their manufacture, thermally insulating and materials that have received reduced heat transfer are used. It also needs a complete sealing of the gate system in order to stop the poisoning of other rooms.

Fireproof bi-fold gates received the most effective system, only this factor helped to make the product really affordable among all fire-resistant systems. The sashes of such structures are securely in contact, therefore, in case of a strong fire, the penetration of smoke into the structure is excluded. Also, special insulation is often applicable; with a slight heating, it begins to increase, thus pressing the sashes against each other. Although the gate system is elementary, the main reliability factors remain at a high level.

Hinged type structures have a canvas, it is equipped with horizontal and vertical rollers. Their number absolutely depends on the total length of the gate. Mineral seals, which are attached around the full perimeter, are glued to prevent them from falling. As a rule, such a canvas is two-layer, and has the required width, this system will withstand the flame for 1 hour. The peculiarity of the gate in the principle of operation, when opening, there is no need to allocate additional space. The sash moves along special rails attached along the contour of the garage where the gate is located.

Refractory roll-type structures and lifting ones characterize a kind of roll, often made of plastic and metal. Such a sleeve includes wooden lining, they are impregnated with a special composition, it does not allow the fire to flare up. A special composition is placed between such a roll and iron, it does not light up, and also received reduced heat transfer.

Such a duo does not burn at all during a fire and remains cool. This gate will resist fire for about 60 minutes. The advantage of such structures lies in the property of PVC - it is not afraid of rust at all. If the filler for the production is metal, that is, special steel, it must be indifferent to the increased load, and also not deform when heated. The difference between panel and roll structures is only in the opening of the leaf, in other words, after opening the gate, the roll version is rolled up when the sectional ones rise and are located along the length of the ceiling.

In addition, the fire-resistant component is the contour, which bypasses the opening along the edge. Often, the contour is made from exactly the same material as the canvases themselves; it received a special “component” that helps to completely clog the room. If a fire occurs, then the penetration of toxins into the garage is practically impossible.

Any refractory structures will simply upgrade. To do this, sensors are attached, they determine the temperature of the room, and also the occurrence of smoke. In addition, if the sensor senses an increase in a certain threshold value, then specialized electric drives start up and automatically seal or open the sashes. These systems effectively increase the fire safety of the existing structure as a whole and, in principle, reliably stop the combustion source.

Article title: Passport for fire gates

Fire barriers are critical structures on which the safety of people depends, therefore fire-resistant doors, gates and hatches are subject to mandatory certification. Stall-Doors products are regularly tested and certified, confirming compliance with the highest standards of quality and reliability.

Basic quality standards for fire doors

The basic documents that are used to control the quality of fire doors are the technical regulations on fire safety requirements (Federal Law No. 123-FZ of July 22, 2008) and GOST R 53307-2009 “Building structures. Fire doors and gates. Stall-Doors products have certificates confirming their compliance with the requirements of these documents.

The fire resistance class, smoke and gas permeability, dimensions and other basic parameters of our company's doors comply with national and international standards. In accordance with the current legislation, metal fire doors, hatches and gates of our production are regularly tested for compliance with the list of standards approved by the Decree of the Government of the Russian Federation of March 10, 2010 No. 304-r:

  • General requirements for fire resistance of building structures comply with GOST 30247.0-94.
  • The fire hazard of products has been tested for compliance with the requirements of GOST 30403-96.
  • Smoke and gas permeability of fire doors and gates complies with the requirements of GOST R 53303-2009.
  • Fire resistance of fire doors and gates complies with the requirements of GOST R 53307-2009.
  • Fire gates and hatches comply with TU 5284-004-87975925-2014.

Compliance of Stall-Doors products with all specified standards is confirmed by certificates issued on the basis of tests. The doors have been tested at the Fire Safety Research Center and have a certificate from the Russian Emergencies Ministry.

The high quality of Stall-Doors products, their reliability and safety are the result of a system of work based on a multi-level quality control system. The effectiveness of the current management system at the enterprise and its compliance with GOST ISO 9001-2011 (ISO 9001:2008) standards is confirmed by a certificate issued by the Federal Agency for Technical Regulation and Metrology.

You can buy Stall-Doors fire doors and gates at the company's head office in Moscow or on the website. Products are supplied with a full package of technical documentation and a service guarantee.